Screw the M5 hexagon socket countersunk
T.
head counterclockwise as shown.
15.4. Tool Calibration
If a replacement motor or drive plate is required, the pruners need to be recalibrated.
Follow next steps to perform the calibration:
1) Remove the upper and lower blades.
2) Insert the battery.
3) Hold down the trigger and keep it pressed. Press the POWER switch again.
4) Maintain the trigger pressed for more than 20 s.
5) Release the trigger when you hear the motor turning.
6) The electric motor rotates during calibration. When the motor stops turning the calibration is
complete.
7) Reassemble the blades as indicated in chapter 15.3
16. Pruner Storage
The most important thing to keep in mind before storing your pruner's lithium ion batteries is to make
sure that the batteries are fully charged up. Storing your battery pack for long extended periods with
little or no charge will damage your battery and void your warranty.
•
Ensure that the battery is fully charge.
•
Avoid storing the device in extremely hot or cold environments.
•
If the device will not be used for a long time, remove the battery before storing it.
•
Batteries and chargers must be placed in a secure location prevent heat, dust and moisture from
entering.
•
Batteries should be stored in a dry environment.
42
T
U. Reduce the friction between the two plans of
the blades by adding grease through the hole of
the plastic cap as shown in the figure.
U