36
5.5 FUEL SEDIMENT CUP SERVICE
Note
Switch fuel valve to the OFF position.
1.
Unscrew the sediment cup using a wrench and remove the O-ring.
2.
Wash the cup and O-ring in a non-flammable solvent and dry thoroughly.
3.
Place the O-ring in the fuel valve, then attach sediment cup. Tighten
securely.
4.
Switch the fuel valve to the ON position and check for leaks. Replace O-ring
if leakage occurs.
HWP & HWT SERIES
Sediment Cup