3.3
Items supplied
Air cleaner, detachable supply cord (only AIC 1000), pre-filter (3×), main filter (3×), operating instructions
Other system products approved for use with this product can be found at your local Hilti Store or at:
www.hilti.group
4
Technical data
4.1
Product properties
For details of the rated voltage, rated current, frequency and/or nominal power input, refer to the
product's country-specific type identification plate.
Dimensions (L × W × H)
Power source
Filter surface area (3 main fil-
ters)
5
Use of extension cords
Use of extension cords
WARNING
A damaged supply cord presents a hazard! Do not touch the supply cord or extension cord if it is damaged
while work is in progress. Disconnect the supply cord plug from the power outlet.
▶ Check the appliance's supply cord at regular intervals and replace it if it is damaged.
•
Use only extension cords of a type approved for the application and with conductors of adequate gauge
(cross section). The appliance may otherwise suffer a drop in performance and the extension cord may
overheat.
•
Regularly check the extension cord for damage.
•
Replace damaged extension cords.
Information on recommended minimum conductor cross-sections and cable lengths is accessible via
a link, in the form of a QR code, at the end of this document.
6
Operation
You achieve optimum cleaning power when you operate the product without hoses connected and with the
shutter open. Depending on the conditions and the application, you can connect an intake hose or position
the product directly in a dust-stop partition wall.
The product has 2 air-cleaning stages. In operation, use stage 2 with the higher cleaning power. The stage 1
setting is only for post-cleaning the air. It can be activated when the room is unoccupied.
Before work starts, remove the air inlet cover.
1. Make sure that the product is steady and cannot topple.
2. To switch on, turn the control switch to the stage 2 position (full power).
3. To switch off, turn the control switch to the OFF position.
6.1
Integration into dust-stop partition wall
You can operate the product with an extraction hose or integrate it directly into a dust-stop partition wall with
the dust-stop partition wall adapter and vacuum dust out of the inside of the dust-stop partition wall without
*2297302*
AIC 1000
492 mm × 419 mm × 674 mm
(19.4 in × 16.5 in × 26.5 in)
1-phase
3.1 m²
(33 ft²)
2
2297302
AIC 1000-E
492 mm × 419 mm × 674 mm
(19.4 in × 16.5 in × 26.5 in)
1-phase
3.1 m²
(33 ft²)
English
5