PROBLEM
CAUSE
NOT
• Isolation valve leaking
HOLDING
• System leaking
DEEP
VACUUM
(WHEN
PUMP
TURNED
OFF)
PLEASE NOTE: All repairs should be carried out by a qualified service technician.
Please contact JAVAC for your nearest service agent.
11.0 SPARE PARTS
JAVAC offer a complete range of product spares. Visit our website: javac.co.uk or contact your local
wholesaler for details.
12.0 WARRANTY
12.1 JAVAC warrants your JAVAC BULLDOG A2L / DV Vacuum pump to be free from defects of
materials or workmanship for one year from the date of purchase. JAVAC does not warrant any
machine that has been subjected to misuse, negligence, accident, repaired or altered by anyone
other than JAVAC.
12.2 JAVAC's liability is limited to machines returned to JAVAC, transportation prepaid, not later than
thirty (30) days after the warranty period expires, and which JAVAC judges to have malfunctioned
because of defective material or workmanship. liability is limited to, at its option, repairing or
replacing the defective machine or part.
ACTION
• Replace valve assembly.
• Leak check system and vacuum lines
(allow for some pressure rise due to
system residual gas)