If you have to change the oven power cord, the earthing (yellow/green)
o
conductor must always be 10 mm longer than the line conductors.
Care must be taken to ensure that the temperature of the mains supply
o
cable does not exceed 50°C.
If the mains supply cable is damaged, then it must be replaced by an
o
appropriate replacement which can be obtained from Spares Department.
INSTALLATION NOTES
1.
The oven has to be installed as indicate d in Fig.4, Whether under a hob or in
a column.
2.
On inserting the oven in a column, it is essential in order to ensure there is
enough ventila tion, to remove the rear pan el of the furniture and have an
opening of at least 85 – 90 mm as indicated in Fig.4.
3.
Check that the oven has been fixed securely in the h ousing. Fixing the oven
into the cupboard is done using 2 screws. One in each side of the oven
door frame.