This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction
NSF Reduction
Aesthetic Effects
Requirements
Chlorine Taste/Odor
50% reduction
*
Particulate Class II
85% reduction
Contaminant
NSF Reduction
Reduction
Requirements
Lead: @ pH 6.5***
0.010 mg/L
Lead: @ pH 8.5***
0.010 mg/L
Mercury: @ pH 6.5
0.002 mg/L
Mercury: @ pH 8.5
0.002 mg/L
Benzene
0.005 mg/L
O-Dichlorobenzene
0.6 mg/L
Toxaphene
0.003 mg/L
Carbofuran
0.04 mg/L
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Use replacement cartridge T2RFWG2, part #4396841.
In Canada, use replacement cartridge T2RFWG2, part
#4396841B. 2007 suggested retail price of $39.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.
Model T1WG2L: When the filter indicator light changes from
green to yellow, order a new filter. When the filter indicator
light changes from yellow to red, it is recommended that you
replace the filter.
Model T1WG2: Change the water filter cartridge every
6 months depending upon your usage. If the water flow to the
water dispenser or ice maker decreases noticeably before
6 months have passed, replace the water filter cartridge more
often.
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
*
Class II particle size: 1 um to <5 um
**
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
***
Compliant for Lead reduction requirements under NSF/ANSI Standard 53 as tested by Pace Analytical Services, Inc.
® NSF is a registered trademark of NSF International.
All manuals and user guides at all-guides.com
Base Grille Water Filtration System
Model T1WG2L/T2RFWG2 Capacity 200 Gallons (758 Liters)
Model T1WG2/T2RFWG2 Capacity 200 Gallons (758 Liters)
System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, Particulate
Class II*; and against NSF/ANSI Standard 53 for the reduction of Mercury,
Benzene, Toxaphene, O-dichlorobenzene, and Carbofuran.
Average
Influent
2.0182 mg/L
1333333 #/mL
Average
Influent
0.1533 mg/L
0.1400 mg/L
0.0058 mg/L
0.0059 mg/L
0.0154 mg/L
1.7571 mg/L
0.015 mg/L
0.0819 mg/L
Influent Challenge
Maximum
Concentration
Effluent
2.0 mg/L ± 10%
0.06 mg/L
At least 10,000 particles/mL
6600 #/mL
Influent Challenge
Maximum
Concentration
Effluent
0.15 mg/L ± 10%
0.0005 mg/L
0.15 mg/L ± 10%
0.0007 mg/L
0.006 mg/L ± 10%
0.0002 mg/L
0.006 mg/L ± 10%
0.0005 mg/L
0.015 mg/L ± 10%
0.0012 mg/L
1.8 mg/L ± 10%
0.0250 mg/L
0.015 mg/L ± 10%
0.001 mg/L
0.08 mg/L ± 10%
0.0400 mg/L
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
Refer to the "Assistance or Service" section for the
Manufacturer's name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Average
Minimum %
Effluent
Reduction
0.0536 mg/L
97.03
**
2325 #/mL
99.51
Average
Minimum %
Effluent
Reduction
0.0005 mg/L
99.67
0.0006 mg/L
99.50
0.0002 mg/L
96.54
0.0003 mg/L
91.57
0.0006 mg/L 92.22
0.0066 mg/L 98.58
0.001 mg/L
93.33
0.0213 mg/L 51.13
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 gpm (1.9 Lpm) @ 60 psi
Average %
Reduction
97.34
99.83
Average %
Reduction
99.67
99.57
96.54
94.92
96.34
99.63
93.33
74.00
13