TIMER / CLOCK FUNCTION: When the steam function is activated, press the 'MODE'
'MODE' screen switches to the TIME icon. The MIN icon appears, and the timer is displayed. You can press the 'PLUS'
'MINUS'
button to set the desired time. The time step is two minutes for setting the timer. The time limit is from 0 to 60 minutes.
The default time is 30 minutes. When the time reaches '00', the steam generator stops working. If you want to extend the steam,
you need to press the 'STEAM'
VENTILATION FUNCTION: Press the 'VENTILATION'
again to stop the fan operation.
LIGHT FUNCTION: Press the 'LIGHT'
RADIO FUNCTION: Press the 'MUSIC'
the 'MODE'
button on the control panel until the 'MODE' screen becomes the TUNE icon, and the frequency window displays
the current frequency. Press the 'PLUS'
FM87.5-108MHz). Press and hold the button for half a second to perform an automatic station search. Press the 'MUSIC'
again, the radio icon dims, and the radio turns off.
BLUETOOTH FUNCTION: Press the 'BLUETOOTH'
the 'PHONE'
button when receiving a phone call.
VOLUME ADJUSTMENT: When the radio or Bluetooth is activated, press the 'MODE'
'MODE' display switches to the VOLUME icon. Press the 'PLUS'
after 3 seconds, the volume increases or decreases continuously.
OZONATOR: When all functions (except the light) are turned off, press the 'O3'
up, and the ozonator starts working. Press the 'O3'
atmosphere of the shower cabin. The ozonator may emit a blue light and produce a slight "crackling" sound.
SAFETY: In case of discomfort, press the 'ALARM'
and the alarm sounds. This stops the steam generator and turns on the fan and light. Simply press the 'POWER BUTTON'
turn off the alarm.
Malfunctions Type
Can't turn on the system,
no display on the screen
Light, Fan don't work
The control panel display '
no steam come out
The control panel dispaly 'E0',
wrong temprature
Practicing hammam poses no risk for children, pregnant women, and elderly individuals. However, it is
advisable to consult a doctor for children under 5 years old and pregnant women. Similarly, for elderly
individuals, a medical authorization is required for hammam sessions beyond the age of 70.
1. It is recommended to never exceed 45°C when setting the temperature of the steam room bath.
2. Never use the steam room after a heavy meal or while in the process of digestion.
3. It is not recommended to use the steam room for more than 30 minutes.
4. It is recommended for people suffering from heart disease, hypertension, and in general, acute illnesses, to consult a
doctor before using the steam room.
5. During the steam room session, be careful not to place your feet near the steam outlet nozzle to avoid burns.
6. The steam diffuser contains an absorbent sponge that can be soaked with essential oils to fragrance your steam room
session. We recommend using special steam room essential oils. Essential oils are powerful natural products that should
be used with caution:
- Essential oils are not recommended for children or pregnant or breastfeeding women.
- Seek medical advice before use in the steam room, especially if undergoing medical treatment or have chronic
illnesses (asthma, epilepsy, allergies, hormone-dependent pathologies...).
- Do not use for prolonged periods.
- Avoid exposure to sunlight after using photosensitizing essential oils.
- In case of irritation, accident or complications, stop using and consult a doctor or emergency services.
INSTRUCTION MANUAL FOR COMPUTER PANEL
button again.
button to turn on or off the ceiling light.
button on the panel once, the radio icon lights up, and the radio starts to work. Press
or 'MINUS'
MAJOR ELECTRICAL MALFUNCTIONS AND SOLUTIONS
1. No power connection (Connect power supply).
2. Check whether there is output AC12V from the transformer secondary, if no voltage, check whether there is AC220V.
on primary, if there is 220V voltage, then transformer is broken.
3. If there is AC12V output, then control system is broken.(replace).
1. Check the output voltage of light (AC12V) and fan (DC 12V), if voltages are ok, then light or fan is broken. (Replace).
2. If there is no voltage on output of light and fan, then control system is broken.
' ,
1. There is no water in the water box.
2. Check if the water supply valve is open.
1. Check whether the temperature probe is damaged or not install well.
button to activate the fan. You can press the 'VENTILATION'
button on the control panel to search for stations (Frequency range:
button, search for "XWM01" on the mobile phone, and connect it. Press
or 'MINUS'
button to adjust the volume. Press the button
button on the control panel, the 'O3' icon lights
button again, the ozonator stops working. The ozonator disinfects the
button on the control panel for an emergency stop. The alarm icon flashes,
Analysis (Solutions)
CAUTION
23
button on the control panel until the
button on the control panel until the