Door Reversibility
Tool required: Philips screwdriver, Flat bladed screwdriver, Hexagonal spanner.
Ensure the unit is unplugged and amply.
To take the door off, it is necessary to tilt the unit backwards. You should rest the unit on something
solid so that it will not slip during the door reversing process.
All parts removed must be saved to do the reinstallation of the door.
Do not lay the unit flat as this may damage the coolant system.
It's better that 2 people handle the unit during assembly.
Required tools: Flat screwdriver, cross (Phillips) screwdriver, spanner.
1.
Carefully remove the hinge cover using a flat screwdriver.
2.
Unscrew the upper hinge.
3.
Remove the hole cover
4.
Transfer it from left to right, then remove the upper door and place it on a flat padded surface
to prevent it from being scratched.