Cleaning metal grease filters
The filters must be cleaned every 2 months of
operation, or more frequently for particularly heavy
usage, and can be washed in a dishwasher.
• Remove the Filters one at a time, pushing them
towards the back of the unit and at the same time
pulling downward.
• Wash the Filters without bending them, and
leave them to dry completely before replacing.
(If the surface of the filter changes colour as time
goes by, this will have absolutely no effect on the
efficiency of the filter itself.)
• Replace, taking care to ensure that the handle
faces forwards.
• No water can be present in filters before installing
back in hood.
Replacing Activated Charcoal Filter
The filter is not washable and cannot be regenerated,
and must be replaced approximately every 4 months
of operation, or more frequently for particularly heavy
usage.
• Remove the Filters one at a time, pushing them
towards the back of the unit and at the same time
pulling downward.
• Remove the saturated charcoal filter by releasing
the fixing hooks.
• Fit the new filter and fasten it in its correct position.
• Replace, taking care to ensure that the handle
faces forwards.
CAUTION: When used in recirculation mode, to Re-
duce the Risk of Fire and Shock use only conversion
kit Model FILTER2.
Lighting Unit
• LED lights must be replaced by Faber factory authorized service.