Operation of the device
FUNCTIONALITIES
Operation modes
The manufacturer's units can operate in both room temperature mode (TH) and in water
supply temperature mode (LWT).
Room temperature mode is not currently functional in Airzone systems, and the unit must
always be previously configured to function only in water supply mode (LWT).
The Aidoo device will be able to regulate the temperature in two circuits in water supply
mode.
DHW control
The manufacturer's units allow you to manage domestic hot water (DHW) production status
control.
The "Powerful" function can be activated in DHW production status control, which forces the
DHW to reach a temperature that has been preset in the configuration of the unit. If DHW is
turned off, it will not be possible to activate this parameter.
Status modes
The unit status can be selected from the Airzone device, enabling on/off control of the unit,
after having performed the necessary configuration and wiring. The unit status can be
controlled in both water supply mode and in domestic hot water production mode (DHW).
The selectable status mode values are Cooling mode, Heating mode and Auto mode. If the
unit is operating in Auto mode, its operation will depend on the outdoor temperature and the
thermostat room temperature.
Set-point temperature
The unit temperature will depend on the operation mode:
The unit must be previously configured to function in LWT mode, so the water supply
temperature at which the unit is to operate must be selected.
The DHW temperature can be selected within the ranges set by the unit's own main
thermostat.
The temperature limits can be obtained via protocol for LWT mode and for DHW production
status control, and they depend on the unit model.WW