20 www.aeg.com
• Do not let the power cable to heat up
to a temperature higher than 90° C.
Make sure that you connect the blue
neutral cable to the terminal with a letter
"N" on it. Connect the brown (or black)
phase cable to the terminal which has a
letter "L". Keep the phase cable connec-
ted at all times.
8.3 Replacement of the
connection cable
To replace the connection cable use on-
ly H05V2V2-F T90 or equivalent type.
Make sure that the cable section is appli-
cable to the voltage and the working
temperature. The yellow/green earth
wire must be approximately 2 cm longer
than the brown (or black) phase wire.
8.4 Building In
min.
55 mm
480 mm
10 mm
min.
min.
650 mm
100 mm
30 mm
560 mm
3 mm
11 mm
A)
supplied seal
B)
supplied brackets
8.5 Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must
be easy to remove and let an easy ac-
cess in case a technical assistance inter-
vention is necessary.
A
A)
Removable panel
B)
Space for connections
11 mm
B
CAUTION!
Install the appliance only on a
worktop with flat surface.
30 mm
min 20 mm
A
(max 150 mm)
60 mm
B
A