1) Shut off the water supply.
2) Flush the toilet to remove the water inside the
tank.
3) Remove the tank lid and place somewhere safe.
NOTE: Before removing anything from the tank, note the
the drain valve.
clockwise with the chain hook still attached to the
trip lever (ill.1).
6) Unhook the chain from the trip lever and remove
7) Unscrew the three screws from the drain valve
body.
IMPORTANT: Make sure not to turn more than seven full
turns as the black mounting block can fall into the water
channel.
8) Remove the drain valve body from the tank (ill. 3).
9) Replace the drain valve in the same position as
the former drain valve.
10)Tighten the screws, applying light torque on each screw
three screws.
part.
13) Turn the water supply back on and check for any leak after the tank has been
CEFIONTECT® CLEANING INSTRUCTIONS
WHAT IS CEFIONTECT®?
WHAT IS CEFIONTECT®?
CEFIONTECT® is TOTO's super-smooth permanent glaze that prevents
debris from sticking to surfaces. Products with the letter "G" in the
number have the CEFIONTECT® glaze. This glaze, along with regular
cleaning, will help keep your TOTO product in pristine condition.
NOTE:
For best results to keep your TOTO product with CEFIONTECT® clean:
• Lavatory: Use a mild dish detergent with a clean, soft cloth.
• Toilet: Use a gel based cleaner with a soft bristled-plastic brush.
• Don't use cleaners, polishing powders or detergents that have gritty
or coarse particles.
• Don't use bleach, chemical thinners or products that have acid or
alkaline detergents listed as ingredients.
• Don't use metal scrub brushes or steel wool.
Following these instructions will ensure that your TOTO product with
the CEFIONTECT® glaze will always stay intact, keeping your product
like new for years to come!
MAINTENANCE INSTRUCTIONS
Replacing the Drain Valve
8
ill. 1
Flush Tower
Drain Valve
ill. 2
ill. 3
Drain Valve
No CEFIONTECT®
With CEFIONTECT®
Refill Tube
Overflow
Tube
Body