30
5.4
NON-COMBUSTIBLE FACING MATERIAL
EN
WARNING: Non-combustible facing material must not project more than 4" (101.6mm) from the face of the
door (all four sides). If greater projections are desired, increase the clearance to the sides and top by 2"
(50.8mm) for every additional 1" (25.4mm) of projection. If using an optional surround, the same rule applies,
starting from the top of the surround. Ensure clearances are maintained for surround removal, as it must lift
off the appliance for maintenance.
A
A
3"(76.2mm)
2" (50.8mm)
0" (0mm)
OPTIONAL
SURROUND
W415-1540 / D / 03.23.17
NON-COMBUSTIBLE FACING MATERIAL
6" (152.4mm)
5" (127mm)
4" (101.6mm)
TOP OF
APPLIANCE
DOOR
SECTION A - A
B
B
3"(76.2mm)
2" (50.8mm)
0" (0mm)
SECTION B - B
71.6
6" (152.4mm)
5" (127mm)
4" (101.6mm)
TOP OF
APPLIANCE
DOOR