Thetford SANICON 400S Mode D'emploi page 2

Table des Matières

Publicité

Overview
Follow the instructions below to attach the SANICON® 400S to
the RV coach.
Read and understand the warnings listed in this docu-
NOTICE
AVISO
AVIS
ment before you install, operate, or service this system. If
!
!
!
!
ATTENTION
CAUTION
ATENCIÓN
DANGER
ATTENTION
ATTENTION
ATTENTION
you do not obey these warnings there is a risk of property
loss, injury, or electrocution. Do not make any changes to
this unit as this could result in property damage, injury, or
electrocution.
Thetford Corporation accepts no responsibility or liability for
damage to equipment, injury, or death that may result from the
system's improper installation, service, or operation.
Thetford Corporation recommends that plumbing and electrical
work be performed by a licensed tradesperson. Local permit and
code compliance is required.
Contents
(1x) SANICON® Turbo 400S Assembly - with OT (over-
temperature) protected pump
(1x) Hose and Nozzle Assembly with nozzle caps
(1x) Hanger Strap
(1x) Fuse Holder
35 AMP Fuse
(1x) Switch Box Assembly
(2x) Electrical Connectors
Owner's & Installation Manual
(2x) Labels with serial #
Pipe Hanger
(1x) 1/4" Bolt and Nut
Required Materials (Not Provided)
Plumbing and End Caps (if necessary)
Wiring
Mounting Hardware
Schedule 30, 40, 80, or DWV rated hard pipe fi ttings or
minimum 10 PSI fl exible pipe rating for pressure side of
pump.
General Guidelines
Gray water bypass can be achieved by plumbing the discharge
line in a manner that gravity can allow liquid to fl ow to the hose
with no upward plumbing.
All systems rely on gravity to move the liquid waste to the pump;
therefore, make sure that the pump inlet is mounted below the RV
holding tank.
Plan the installation so that the pump does not extend beyond the
side of the coach
®
SANICON
Turbo Model 400S - Permanent Bayonet Mount
Installation
Each assembly comes with two labels. One label should be
placed in the hose compartment; the other should be placed in the
Owner's & Installation Manual.
If black and gray tanks are heated, treat SANICON® Turbo
400S in same manner.
Duty Cycle: Intermittent, fi ve minutes continuous operation;
20 minutes off.
It is important to plumb hose avoiding sharp angles or
bends during use or storage.
Placement of the hose connection MUST be serviceable by
the customer.
Warnings and Cautions
Read and understand the warnings and cautions listed in this
document before you install or operate this unit.
NOTICE
AVISO
CAUTION
AVIS
!
NOTICE
Thermal Cut-Off Switch
Because SANICON
duty, the pump contains a thermal-cut-off switch for your safety.
Typical run time is 15-20 minutes of pumping before the pump
turns itself off and needs to cool for at least 20 minutes before the
thermal-cut-out resets and the pump can run again.
■ If the pump is run immediately after a thermal reset, it will run
for approximately 5-8 minutes.
■ If allowed to cool for several hours it will run the full 20 min-
utes.
Questions?
If you have any questions or need assistance, please contact
Technical Support at 1-800-444-7210, available Monday through
Friday 8 a.m. to 6 p.m., Eastern Standard Time.
2
Do not make any changes to this unit, as this could result
in property damage or injury.
Gray and black water tanks MUST BE COMPLETELY
FREE FROM DEBRIS before installing and operating the
pump. Failure to comply with this warning could result in
a voided product warranty and equipment failure.
Plumbing from pump to storage compartment MUST be
Schedule 30, 40, 80, or DWV rated
plumbed with
hard pipe fi ttings or minimum 10 PSI fl exible pipe
rating for pressure side of pump.
The installation site of the pump MUST be able to support
a minimum of 30 pounds.
Plan for suffi cient clearance under the RV once the SANI-
CON® system is installed. Lowest point of unit MUST be
above axles of coach.
The pump is suitable for indoor and outdoor use.
®
Turbo pumps are designed for intermittent
97652 Rev. C (04.05.18)

Publicité

Table des Matières
loading

Table des Matières