SERVICE AND ADJUSTMENTS
WASH ERS
RE TAIN ING
RING
AXLE COVER
SQUARE KEY (REAR
WHEEL ONLY)
TO START ENGINE WITH A WEAK BATTERY
(See Fig. 35)
WARNING: Lead-acid batteries gen-
er ate ex plo sive gases. Keep sparks,
flame and smoking ma te ri als away from
bat ter ies. Always wear eye pro tec tion
when around batteries.
If your battery is too weak to start the engine, it should be
recharged. (See "BATTERY" in the MAINTENANCE sec-
tion of this man u al).
If "jumper ca bles" are used for emer gen cy starting, follow
this pro ce dure:
IMPORTANT: YOUR TRACTOR IS EQUIPPED WITH A 12 VOLT
SYSTEM. THE OTHER VEHICLE MUST ALSO BE A 12 VOLT
SYSTEM. DO NOT USE YOUR TRACTOR BATTERY TO START
OTHER VEHICLES.
TO ATTACH JUMPER CABLES -
Connect one end of the RED cable to the POSITIVE
(+) terminal of each battery(A-B), taking care not to
short against tractor chassis.
Connect one end of the BLACK ca ble to the NEGA TIVE
(-) terminal (C) of fully charged battery.
Connect the other end of the BLACK cable (D) to good
chassis ground, away from fuel tank and bat tery.
TO REMOVE CABLES, REVERSE ORDER -
BLACK cable first from chassis and then from the fully
charged battery.
RED cable last from both batteries.
WEAK OR DEAD
BATTERY
FIG. 34
FULLY CHARGED
BATTERY
FIG. 35
REPLACING BATTERY (See Fig. 36)
WARNING: Do not short battery ter mi nals by allowing
a wrench or any other object to contact both terminals at
the same time. Before connecting battery, remove metal
bracelets, wristwatch bands, rings, etc.
Positive terminal must be connected first to prevent spark-
ing from ac ci den tal grounding.
Lift hood to raised position.
Disconnect BLACK battery cable (A) then RED battery
cable and carefully remove battery from tractor.
Install new battery with terminals in same position as
old battery.
First connect RED battery cable (B) to positive (+) battery
terminal with hex bolt and keps nut as shown. Tighten
securely. Slide terminal cover (C) over terminal.
Connect BLACK grounding cable to negative (-) bat tery
terminal with re main ing hex bolt and keps nut. Tight en
securely
Close hood.
C
B
Positive
(Red)
Cable
25
Negative
A
(Black)
Cable
02954
FIG. 36

Publicité