PLAN VENT SYSTEM
Choose
your
exhaust
installation
type
Recommended
exhaust installations
Typical installations vent the dryer from the rear of the dryer.
A
¸
B
......... i.............................. F
A. Dryer
B. Elbow
C. Wall
D. Fxhaust
hood
E. Clamps
£ Rigid metal
or flexible
metal
vent
G. Vmlt I_'ngth necessary
to connect
elbovw
H. Fxhaust
outlet
Standard
exhaust installation
with
rigid metal or flexible
metal vent
Alternate
installations
for close clearances
Venting
systems come
in many w_rieties.
Select the type best for your installation.
|wo close-
clearance
installations
are shown.
Refer to the manufacturer's
instructions.
A
B
C
A. Over-the-top installation (also available with one
offset elbow)
B. P_'riscope inst_llation
C. Rear exhaust installadon to left or right sidle
NOTE: The following
kits for close clearance
alternate
installations
are available
for purchase.
Please see the "Assistance
or Service"
section of this manual
to order.
•
Over-the-]bp
Installation:
Part Number
4396028
•
Periscope
Installation
(For use with dryer vent to wall vent mismatch):
Part Number
4396037
- 0" (0 cm) to 18" (45.72 cm) mismatch
Part Number
4396011
- 18" (45.72 cm) to 29" (73.66 cm) mismatch
Part Number
4396014-
29" (73.66 cm) to 50" (127 cm) mismatch
•
Rear exhaust
installation
to left or right side:
Part Number
8212504
Special provisions for mobile home installations
The exhaust
vent must be securely
fastened to a noncombustible
portion
of the mobile
home
structure
and must not terminate
beneath
the mobile
home. Terminate
the exhaust
vent
outside.