A.
Control Panel
NOTE: Total power drawn from all receptacles must not exceed the
nameplate ratings.
B.
120 Volt GFCI Receptacle
Ground Fault Circuit Interrupter duplex receptacle is rated so that a
total of 20 amps may be drawn regardless of whether both halves or just
one receptacle is used. This receptacle may be used along with other
receptacles provided the generator is not overloaded and total power
drawn is kept within nameplate ratings.
Ground Fault Circuit Interrupter
(Conforms to U.L 943, Class A and NEC requirements)
This device protects you against hazardous electrical shock that may
be caused if your body becomes a path through which electricity travels
to reach ground. This could happen when you touch an appliance or cord
that is " live " through faulty mechanism, damp or worn insulation, etc.
The GFCI receptacle cannot be reset once tripped, unless the
generator is running and power is available to it. Test regularly to assure
proper operation.
C.
120 Volt, 30 Ampere Twistlock Receptacle
You may draw a maximum of 30 amps from this receptacle. If
other receptacles are used at the same time, total power used must be kept
within nameplate ratings.
D.
120/240 V, 30 Ampere Twistlock Receptacle
Maximum full load current may be drawn from the 120/240 volt
receptacle, provided it is the only receptacle used. Total current must be
limited to the nameplate rating. If the 120/240 volt receptacle is used
along with the 120 volt receptacle, the total load drawn must not exceed
the nameplate ratings.
E.
Circuit Protectors
The receptacles are protected by an AC circuit protector. If the
generator is overloaded or an external short circuit occurs, the circuit
K
Q
R
J
I
English
GENERA
T
OR FEA
GENERA
T
OR FEA
protector will trip. If this occurs, disconnect all electrical loads and try to
determine the cause of the problem before attempting to use the generator
again. If overloading causes the circuit protector to trip, reduce the load.
NOTE: Continuous tripping of the circuit protector may cause
damage to generator or equipment. The circuit protector may be reset
by pushing the button of the protector.
F.
G.
H.
I.
J.
K.
L.
M. Oil Drain Plug
N.
O.
P.
Q.
R.
N
O
T
H
M
6
TURES
TURES
Ground Terminal
Hour Meter
Engine On/Off/Start Switch
420 CC OHV Engine
Recoil Starter
Engine Choke Lever
Oil Filler Cap
6.5 Gallon Metal Fuel Tank
Fuel Tank Cap
Fuel Gauge
Fuel Shut-Off Valve
Air Filter
P
G
L
B
S
Customer Hotline 1-800-445-1805
E
E
C
D
F
A