the scope of supply).
When installing, never hang the equipment by the
discharge line or by the power cable. The equip-
ment must be hung up with the provided carry
handle or it must rest on the bottom of the shaft.
To ensure that the equipment works properly, the
bottom of the shaft always must be free of sludge
and other accumulations of dirt. If the water level
is too low, the sludge in the shaft can quickly dry
out and hinder the equipment from starting. It is
necessary therefore to check the equipment regu-
larly (carry out trial start-ups).
The pump shaft should be large enough.
5.2 Mains connection
Danger!
The equipment you have purchased comes with
an earthing-pin plug. The equipment is designed
for connection to a socket outlet with earthing
contact for 230 V ~ 50 Hz. Make sure that the
socket-outlet is sufficiently fused (at least 6 A)
and in good working order. Insert the power plug
in the socket-outlet and the equipment is ready
for operation.
6. Operation
You can put the equipment into operation after
you have thoroughly read the installation and ope-
rating instructions. Pay attention to the following
points:
•
Make sure that the equipment is set up secu-
rely.
•
Check that the discharge line is fitted correct-
ly.
•
Make sure that the electrical connection is
230 V ~ 50 Hz.
•
Check that the electrical socket-outlet is in
good working order.
•
Make sure that no moisture or water can ever
reach the power connection.
•
Make sure that the equipment does not run
dry.
•
To switch off the equipment, pull the power
plug out of the socket outlet.
Anl_GC_SP_2275_SPK13.indb 16
Anl_GC_SP_2275_SPK13.indb 16
GB
Setting the On/Off switching point:
The ON/OFF switching point of the floating switch
can be adjusted by shifting the floating switch in
the floating switch notched holder (Fig. 3/Item 5).
•
The floating switch must be fitted so that the
switching point height: ON and the switch
point height: OFF can be reached easily and
with little force. Check this by placing the
equipment in a container filled with water
and carefully raising and lowering the floating
switch with your hand. You can then see whe-
ther the equipment switches on and off.
•
Make sure that the distance between the floa-
ting switch head and the cable holder is not
too smaller than 10 cm. If the distance is too
small, there is no guarantee that the equip-
ment will work correctly.
•
When adjusting the floating switch, make
sure that the floating switch does not touch
the bottom before the equipment is switched
off. Important! Risk of dry running.
Manual operation:
For manual operation place the lock for the float
switch (5) on the pump (Fig. 2). Mount the floating
switch as illustrated in Fig. 1. The equipment will
then run continuously. To prevent dry running, this
operating mode is allowed only under supervi-
sion. The equipment must be switched off (pull
out the power plug) as soon as no more water is
emitted from the discharge line.
7. Replacing the power cable
Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
- 16 -
21.01.2021 12:47:07
21.01.2021 12:47:07