Télécharger Imprimer la page

Danfoss RET2001RF Guide D'installation page 4

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
Installation Guide
1. Installation Steps
EN
User Guide can be downloaded from: heating.danfoss.com.
1. Installation must be done by an authorised
electrician.
2. The room thermostat should be installed at approx.
1.5 m above oor and where the e ects of sunlight,
draught or other heat sources (eg. TV's) are avoided,
see g. 1 on page 64.
3. Decide location of RX1-S V2 receiver, ensuring a
minimum space of 30cm from boiler housing. There
must be no large metal objects, such as boiler cases
or other large appliances, in line of sight between
the thermostat and the receiver as this will prevent
RF communication, see g. 1 on page 64.
4. Remove and mount RX1-S V2 back plate direct
to wall or on wall box, and wire as required for
application, see g. 2 on page 64.
5. Locate hooks at top of RX1-S V2 into top of back
plate and lower into position and tighten retaining
screw. Switch on mains power to start RF pairing.
6. Loosen lower retaining screw of thermostat and
carefully remove back plate, see g. 3 on page 64.
7. Insert 2 x AA Alkaline batteries to front part taking
care to insert correctly as indicated. Check RF
connection between Thermostat and RX1-S V2
Receiver before xing in nal position, see RF Pairing
below.
4
AN30483490055001-000103
RET2001RF & TP5001RF

Publicité

loading

Ce manuel est également adapté pour:

Tp5001rf