FBX2-FBX4-FBX6-FBX8 - User's manual
Antiremoval Protection Tamper
3mm max.
Antiremoval Protection Tamper
Assemblage protection
only on not ferrous
materials.
Connections
3B
8
Positioning the magnet
in correspondence with
the reference point
marked behind the receiver
IR COM
12Vcc
24H
Ne
Black
Blu
Red
barrier
Interface Unit
IR
Allarme
Blu
Ro
24h
3B
security
LED DISPLAY
2 leds are present on the interface
barrier card:
LED 1 - Yelloow (it points out
the state of communication
between the barrier and the
interface card)
Led OFF: it points out the
correct communication between
the barrier and interface card.
Led ON: points out the missed
communication between the
barrier and the interface card
(possible cause due to a
superior 50mt cable length
between the barrier and
interface card).
Flashing Led: Flashing Led:
communication with presence
of errors; using a screened
cable (3B) and verifying its
length not superior to 50mt.
LED 2 - Red (it Points out the
alert state)
Led OFF: in line barrier
Led ON: one or more beams of
the interrupted barrier
Buzzer
Electronic control board is
equipped with a buzzer ; this is
switched on when one or more light
beams are obstructed .
This buzzer can be disabled
configuring SW7 in the OFF
position . It may be used during
installation helping operator
to find best light beam alignment or
it may be used during normal
working operation indicating light
beam obstruction
warning condition.