Télécharger Imprimer la page

Hiltron security FBX2 Mode D'emploi page 6

Publicité

Les langues disponibles

Les langues disponibles

FBX2-FBX4-FBX6-FBX8 - User's manual
Programmation
Programmation
On the interface card is present a switch with 8 positions.
On the interface card is present a switch with 8 positions.
SWITCH1/SWITCH2 - Barrier selection FBX2-FBX4-FBX6-FBX8
SWITCH1/SWITCH2 - Barrier selection FBX2-FBX4-FBX6-FBX8
According to the models of purchased barriers, the first two SWITCH are settedi in factory in the following
According to the models of purchased barriers, the first two SWITCH are settedi in factory in the following
ways:
ways:
ON
5
6
7
8
FBX2
FBX2
2 beams
2 beams
ATTENTION: Don't select a different model from the one really installed.
ATTENTION: Don't select a different model from the one really installed.
ON
Power emanation infrared light= LOW
Power emanation infrared light= LOW
This configuration is recommended
for an operating gap inferior to 4 meters.
In such condition, the transmission power
of the infrared beam is limited
not to create interferences.
SWITCH4 - Activation alarm on single beam breakage or more beams
SWITCH4 - Activation alarm on single beam breakage or more beams
ON
Alarm output is
Alarm output is
activated to the breakage of one
activated to the breakage of one
or more beams and respecting the defined times
or more beams and respecting the defined times
SWITCH5 - Configuration breakage times of beams for alarm activation
SWITCH5 - Configuration breakage times of beams for alarm activation
ON
Activation alarm on long term breakage
Activation alarm on long term breakage
Alarm output is activated to the interception of one of the following
Alarm output is activated to the interception of one of the following
events:
events:
Continuous breakage of 1 beam, for more than 2 seconds
Continuous breakage of 1 beam, for more than 2 seconds
(valid condition only when the SWITCH4 is OFF)
(valid condition only when the SWITCH4 is OFF)
Breakage of 2 adjacent beams for more than 1
Breakage of 2 adjacent beams for more than 1
Breakage of 2 non adjacent beams for more than 0,5 seconds
Breakage of 2 non adjacent beams for more than 0,5 seconds
(only FBX4, FBX6,FBX8)
(only FBX4, FBX6,FBX8)
Breakage of 3 or more beams for more than 0,4 seconds (only
Breakage of 3 or more beams for more than 0,4 seconds (only
FBX4, FBX6,FBX8)
FBX4, FBX6,FBX8)
SWITCH6 - Detection of fast obstruction on infrared beam
ON
If SW6 is configured in the ON position , output alarm
on the edge connector is activated when infrared beam
is obstructed for a minimum time of 150 millisecond
SWITCH7 - Activation buzzer on prealarm condition
ON
The device buzzer comes activated when
an prealarm condition is found
NOTE: the 8 SWITCH is reserved
NOTE: the 8 SWITCH is reserved
6
ON
5
6
7
8
FBX4
FBX4
4 beams
4 beams
SWITCH3 - Configuration operating gap
SWITCH3 - Configuration operating gap
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
ON
5
FBX6
FBX6
6 beams
6 beams
Power issue infrared light = HIGH
Power issue infrared light = HIGH
Configuration for an operating gap
The transmission power of the
Anti-bugs feature
Anti-bugs feature
activated only when 2 or more beams are breaked
activated only when 2 or more beams are breaked
Alarm activation on a short time breakage
Alarm activation on a short time breakage
Alarm output is activated to the interception of one of the following
Alarm output is activated to the interception of one of the following
events:
events:
Continuous breakage of 1 beam, for more than 1 (valid
Continuous breakage of 1 beam, for more than 1 (valid
condition only when the SWITCH4 is OFF)
condition only when the SWITCH4 is OFF)
Interruption of 2 rays (adjacent or not adjacent) for greater once
Interruption of 2 rays (adjacent or not adjacent) for greater once
of 0,5 seconds
of 0,5 seconds
Breakage of 3 or more beams for more than 0,3 seconds (only
Breakage of 3 or more beams for more than 0,3 seconds (only
FBX4, FBX6,FBX8)
FBX4, FBX6,FBX8)
If SW6 is configured in the OFF position ,
filter time to activate output alarm on the edge
connector is indicated in description of the switch SW5
The device buzzer never does not come activated
security
ON
ON
ON
6
7
8
FBX8
FBX8
8 beams
8 beams
ON
5
6
7
8
superior to 4mt.
infrared beam is not limited.
ON
5
6
7
8
Alarm output is
Alarm output is
and respecting the times
and respecting the times
(Anti bugs feature is active)
(Anti bugs feature is active)
ON
5
6
7
8
ON
5
6
7
8
ON
5
6
7
8
5
6
7
8

Publicité

loading

Ce manuel est également adapté pour:

Fbx4Fbx6Fbx8