Télécharger Imprimer la page

RIB AA40833C Mode D'emploi page 41

Publicité

Les langues disponibles

Les langues disponibles

The door lever's length
cannot exceed the 83 cm
1 - BOSS operator
2 - Aerial
3 - Blinker
4 - BLOCK Wi-Fi key selector
5 - Photoelectric cells (internal)
PRE-INSTALLATION CHECK
For doors with a total width up to 2,96 m, maximum height 2,5 m or a total surface area of 9 square metres and door lever's length
with maximum length 83 cm, a BOSS (AA40833) device should be used; mounted as shown in Fig. 3, with a PAIR OF STRAIGHT
LEVERS code ACG8720 (or a PAIR OF CURVED LEVERS code ACG8722), the accessories for LATERAL TRANSMISSION code ACG8725, a
TRANSMIT TUBULAR SHAFT code ACG8710 or a TRANSMIT BAR code ACG8726 and a SHORT MOUNTING PLATE code ACG8189 or LONG
MOUNTING PLATE code ACG8188.
- Check that the available space between the moving frame of the door and external frame with counterweights exceeds 15 mm.
If so, the STRAIGHT LEVERS can be mounted. Otherwise, mount the CURVED LEVERS if the distance is less than 15 mm, making
sure to remain within the assembly parameters described in Fig. 7.
- Check that the up-and-over door slip bearings are not blocked or obstructed and that the counterweight fastening cables are
in correct working order.
- Remove, if present, the manual closing lever connected to the locking device.
N.B. It is obligatory to uniform the characteristics of the door to the standards and laws in
force. The door can be automatized only if in a good state and if in accordance with
EN 12604 standard.
No trapping points must be generated (for example between horizontally pivoted open door
and wall).
4
5
COMMAND TYPE
Hold-to-run operation
Impulsive - in sight
(e.g. push-button)
impulsive - out of sight
(e.g. remote)
automatic
* a typical example are those doors which do not have access to any public way
A: Hold-to-run operation made by push-button ex: code ACG2013
B: Hold-to-run operation made by key selector ex: code ACG1010
C: Adjustable power of the motor or photocells to respect impact forces as indicated in
Annex A
D: Safety strips and/or other additional devices to reduce the probability of contact with
the door.
E: Devices installed in such a way that a person can not be touched by the door.
41
1
Parts to install according to EN 12453 standard
USE OF THE SHUTTER
Skilled persons
Skilled persons
(out of public area*)
(public area)
A
B
C or E
C or E
C or E
C and D, or E
C and D, or E
C and D, or E
G
B
2
3
5
3
Not skilled
persons
Not possible
C and D, or E
C and D, or E
C and D, or E

Publicité

loading

Ce manuel est également adapté pour:

Boss 230v master ip30Aa40833Boss 230v master ip44