If the product is equipped with a vacuum indicator, the operator must be able to view the vacuum indicator at all
times in order to assess whether the existing vacuum is still sufficient.
Personal Protective Equipment
Personal protective equipment must be worn for all work with the trolley to minimise health risks.
Never use the suction lifter in conjunction with a crane or other lifting equipment. The corresponding
prohibitory sign is attached to the suction lifter:
The suction lifter has a specified maximum load capacity. These values only apply to new suction pads and
clean, dry and flat glass panes at an ambient temperature of 20°C and an ambient pressure of 1013 mbar after
generating the maximum vacuum.
Note that the air pressure decreases the higher you are above sea level and therefore also reduces the load
capacity. Starting from 1,600 m above sea level, the use of suction lifters is not recommended.
The holding capacity is significantly reduced up to its total loss in hot, cold, humid, or dirty conditions, in parti-
cular if the suction pad is not maintained or damaged, and when lifting or carrying other materials than flat glass
(e. g. decorative glass, plastic, stone, metal, etc.).
Always check the suitability of the suction lifter for its intended use. Secure the objects to be lifted or
carried against falling or tipping over.
Suction lifters must not be subjected to extreme heat (e. g. open flames, constant direct sunlight). Temperatures
consistently above approx. 40°C must be avoided at all costs.
Suction lifters must not be subjected to extreme cold (e. g. frost). Temperatures consistently below 0°C are not
permissible.