Télécharger Imprimer la page

Proline FP 126 Manuel D'utilisation page 32

Masquer les pouces Voir aussi pour FP 126:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
GB
Error messages
Status of indicator light
90°C 60 °C
40°C
Off
Off
Off
Flash
Off
Off
Off
Off
Flash
If error still exists, please contact the maintenance personnel.
TECHNICAL DATA SHEET
Below is the sheet of household washing machine according to EU Directive 1015/2010.
Manufacturer
Type/Description
Capacity
Spin Speed
Energy efficiency class
Annual energy consumption
Power consumption of off-mode
Power consumption of left-on mode
Annual water consumption
Spin-drying efficiency class
Standard washing cycle
Energy consumption of the standard 60° at full load
Energy consumption of the standard 60°at partial load
Energy consumption of the standard 40°at partial load
Programme duration of standard 60°at full load
Programme duration of standard 60°at partial load
Programme duration of standard 40°at partial load
Water consumption of the Standard cotton 60°C at
full load
Water consumption of the Standard cotton 60°C at
partial load
Water consumption of the Standard cotton 40°C at
partial load
Remaining moisture content of the Standard cotton 60°C
at full load
Remaining moisture content of the Standard cotton 60°C
at partial load
Remaining moisture content of the Standard cotton 40°C
at partial load
Noise level of washing
Noise level of spinning
Mounting
Height
Width
Depth
Power consumption
Rate voltage/frequency
Water pressure
Cause
20°C
Door is not properly
Flash
closed.
Off
Water inlet error
Drainage error
Flash
Solution
Close the door properly.
Make sure the tap is turned on.
Check the water pressure.
Clean the water inlet filter.
Make sure the drain hose is not twisted or
blocked.
Make sure the drain hose is installed correctly.
Clean the drain pump.
33
Proline
FP 126 ,FP 126 E
6 kg
1200 rpm
++
A
173 kWh
0.5 W
0.5 W
9240 L
B
Cotton intensive
0.93 kwh
0.66 kwh
0.63 kwh
273 min
243 min
241 min
48 L
37 L
37 L
50%
55%
55%
58 dB
76 dB
Free standing
850 mm
595 mm
470 mm
2100 W
220-240V/50 Hz
0.05-1 MPa

Publicité

loading

Ce manuel est également adapté pour:

Fp 126 e