Télécharger Imprimer la page

Ravelli VELA 7 Manuel D'utilisation Et D'entretien page 53

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Rev.1 20.02.18
Pag.54
EN
! IMPORTANT
Packaging
When the stove arrives, check:
that it is the model you ordered;
that it has not been damaged during shipping.
Any complaints must be reported to the deliveryman (also on the delivery note) upon receival.
Check the capacity of the floor before handling and positioning the stove.
To handle the stove in its packaging, follow the procedure below:
1
Position the pallet truck forks in the slots under the wooden pallet.
2
Lift slowly.
3
Place the stove near the chosen location for installation.
The stove always needs to be handled vertically. Take extra care to protect the door and its glass against
mechanical impact that could jeopardise their integrity
.
To unpack the stove, follow the procedure described below:
1
Cut the straps and remove the wooden reinforcement frame resting on the box
2
Slowly lift the cardboard box
3
Remove any bubble-wrap or similar
4
Remove the stove from the pallet and position the appliance in the chosen location, ensuring that it is compliant with
the directions.
! IMPORTANT
Set-ups for the smoke evacuation system
Be careful when building the smoke evacuation system and observe the regulations in force in the country where
the stove is installed.
! IMPORTANT
Smoke ducts and fittings
The term smoke duct indicates all ducts that connect the combustion equipment to the chimney.
The following requirements need to be applied:
observe product standard EN 1856-2;
the horizontal sections must have a minimum slope of 3% upwards;
the length of the horizontal section must be as minimum as possible, and its projection on the horizontal plane must not exceed
2 metres;
changes in direction must not have an angle of more than 90° (45° bends are recommended);
the number of direction changes, including the one necessary for insertion into the chimney, must not exceed 3;
the cross section must have a constant diameter, the same from where it exits the firebox up to the fitting into the chimney;
it is forbidden to use flexible metal and fibre cement pipes;
smoke ducts must not cross rooms where the installation of combustion equipment is prohibited.
In any case, the smoke ducts must be sealed against combustion products and condensation, as well as insulated if they lead outside
of the installation room.
Installing manual draught adjustment devices is not allowed.
! IMPORTANT
Use and maintenance manual Vela 7-9
Local administrative regulations and particular requirements of the authorities pertaining
to the installation of combustion appliances, the air intake and the smoke evacuation
system, may vary based on region or nation. Check with your local authorities if there are
stricter laws than set forth herein.
The end user is responsible for disposing of the packaging in accordance with the laws in
force in the country of installation.
The Manufacturer will not be held liable for incorrectly sized and non-regulation smoke
evacuation systems.
Creating an initial straight vertical smoke duct section of at least 1 m to ensure proper
smoke ejection is mandatory.

Publicité

loading

Ce manuel est également adapté pour:

Vela 9