Technical data
Table 1: Tecnical data
Controller input
Max. input voltage (Voc)
55 V DC
Operating voltage
16...55 V DC
Max. current (DC)
6 A
Max. pv short circuit
25 A
current (Isc)
Controller output
55 V BLDC PWM
Max. output voltage
3-Phase
Max. frequency
170 Hz
Max. continuous current
6 A
Max. continuous power
250 W
Case
Enclosure class
IP 68
Protective class
II
General
System storage
-20 °C... +65 °C
temperature
(-4 °F...+149 °F )
Pollution degree
3
classification
Max. altitude rating
2000 m
Overvoltage category
OC II
input/output
Controller ambient
-30 °C... +50 °C
temperature
(-22 °F...+122 °F )
Max. water temperature
50 °C (122 °F)
(pump and motor)
Refer to Table 2
l
Explanation of warning symbols

WARNING
– Disregard can lead to
injury, death or damage the system
WEEE
- The WEEE Symbol means
that a device must be disposed of
separately from general household
waste. When a device reaches the
end of its lifespan, it must be taken
to a designated waste collection
point for safe disposal or recycling.
l
When installing and using this electrical
equipment, basic safety precautions should
always be followed, including the following:
l
WARNING
– To reduce the risk of
injury, do not permit children to use
this product unless they are closely
supervised at all times
l
WARNING
– To reduce the risk of
electric shock, replace damaged
cords immediately
l
WARNING
- Due to local laws an
external fuse might be necessary
l
WARNING
– When the
photovoltaic array is exposed to
light, it supplies a DC voltage to the
controller
WARNING
- Make sure that the
controller is unplugged when
installing the pump system
l
l
WARNING
- Do not try to open
the controller. This will damage the
controller and voids the waranty
WARNING
- Only connect
a
equipment that was provided by
the manufacturer or supplier to
this pump
a
CAUTION
- Keep pump out of
direct sun during installation to
avoid overheating.
CAUTION
- We recommend to use
only one extension cable. Using
multiple extension cables will
reduce system performance.
Figure 1: Pump end naming
PE
Pump end type
07
14
23
Ensure the pump class is suitable for the water
temperature. See Figure 1 and Table 2.
Table 2: Meaning of temperature classes:
Temperature
Water temperature
class
range
2
20 to 30 °C (68 to 86 °F)
3
30 to 40 °C (86 to 104 °F)
4
40 to 50 °C (104 to 122 °F)
S1 HR
XX XX
PASN FNXX HA
Temperature class:
2
= 20 to 30 °C (68 to 86 °F)
3
= 30 to 40 °C (86 to 104 °F)
4
= 40 to 50 °C (104 to 122 °F)