Installing the magnet on the anchor windlass
A hole having a diameter of 6.5 mm (~1/4") and depth of 8 mm (5/16") must be drilled on a tooth
of the gipsy, in a place outside the chain's path.
In the case of vertical shaft anchor windlasses (see Fig. 1B), drill the hole in the lower
circumference of the gipsy.
In the case of horizontal shaft anchor windlasses (see Fig. 2B), drill the hole in the outer
circumference of the gipsy.
Also make sure that the protruding part of the magnet will not collide with the base or sensor
during rotation of the gipsy.
Insert the metal part of the magnet in the hole, allowing the protected part to protrude by about 2
mm. Fix it in place using an adhesive for metals (two-component epoxy glue) or silicone. The
glue used must be able to withstand a marine environment.
Installing the magnetic sensor for vertical shaft anchor
windlasses
(see Fig. 1A – 1B)
Drill a 4 mm (~3/16") hole in the cover through which to thread the
sensor cable.
Fasten Part A of the support with the two screws provided, after
having positioned the O-ring in the lower part of the support.
Fit Part B with the magnetic sensor on support A and adjust its
height until it is aligned with the magnet fastened on the gipsy.
Bring the sensor to a distance of about 3 mm (~1/8") from the
magnet and secure it in place by tightening screw G1. Then tighten
screw G2.
Installing the magnetic sensor for horizontal shaft anchor
windlasses
(see Fig. 2A – 2B – 2C)
Drill a 4 mm (~3/16") hole in the cover through which to thread the sensor
cable.
Fasten Part A of the support with the two screws provided, after having
positioned the O-ring in the lower part of the support.
Cut Part C to measure using a hacksaw. The sensor must be positioned at a
distance of about 3 mm (~1/8") from the magnet.
Fit Part C with the magnetic sensor on support A and fix it in place using an
adhesive for plastic (two-component epoxy glue) or silicone.
Using the same glue, attach the sensor to Part C.
Installing the chain counter
(see connection diagram)
EV-020
17
English
G1
B
G2
A
OR
C
Rev. 11 – 2014
A
OR