Télécharger Imprimer la page

Guardian A5 Manuel D'instructions page 8

Publicité

Les langues disponibles

Les langues disponibles

English
Diagram A -
Connections
8
Inspection
Prior to EACH use, inspect A5 Concrete
Expansion Anchor for deficiencies, including, but
not limited to, corrosion, deformation, pits, burrs,
rough surfaces, sharp edges, cracking, rust, paint
build-up, excessive heating, alteration, broken
stitching, fraying, and missing or illegible labels.
IMMEDIATELY remove A5 Concrete Expansion
Anchor from service if defects or damage are
found, or if exposed to forces of fall arrest.
Ensure that applicable work area is free of all
damage, including, but not limited to, debris,
rot, rust, decay, cracking, and hazardous
materials. Ensure that work area will support the
application-specific minimum loads set forth in
this manual. Work area MUST be stable.
At least every 12 months, a Competent Person
(CP) other than the user must inspect A5
Concrete Expansion Anchor.
See Inspection Log on page 9
Inspections MUST be recorded in inspection
log in instruction manual and on equipment
inspection grid label. The CP must sign their
initials in the box corresponding to the month
and year the inspection took place.
During inspection, consider all applications and
hazards the harness has been subjected to.
Product lifetime is indefinite as long as it passes
pre-use and CP inspections.
This inspection log must be specific to one A5
Concrete Expansion Anchor. Separate inspection
logs must be used for each A5 Concrete
Expansion Anchor. All inspection records must
be made visible and available to all users at all
times. If equipment fails inspection it must be
discarded immediately.

Publicité

loading

Produits Connexes pour Guardian A5

Ce manuel est également adapté pour:

1400052