Télécharger Imprimer la page

DOLD SAFEMASTER STS A Mode D'emploi page 8

Publicité

Les langues disponibles

Les langues disponibles

Technical Data
Mechanical Data
Enclosure:
Locking force:
General Data
Temperature range:
Storage range:
Application:
Coding level low according to DIN EN ISO 14119:2014-03
Dimensional Drawings [mm]
Actuator module A with standard actuator T and closing plate
Actuator module A with closing plate
Variants and Accessories
Since with the actuator module A an actuator slot always remains
open when an actuator is introduced, dirt may enter into the module. In
order to prevent this, a separate closing plate is available which can be
fastened in the open actuator slot like an anchor.
Ordering Designation
Actuator module A
Article number: 0061872
Closing plate
Article number: 0064619
E. Dold & Söhne GmbH & Co. KG • D-78120 Furtwangen
dold-relays@dold.com • www.dold.com
Stainless steel V4A / AISI 316 / AISI 630
F
4000 N
zh
(in a locked unit e.g M10A)
- 40°C to + 100°C
- 40°C to + 100°C
only as part of a unit of the
SAFEMASTER STS series
Safety Related Data
Data suitable for the PFH
summation method according to
D
EN ISO13849-1:2016
Data
according
to EN
ISO13849-
1:2016
Category
2
PL
d
PFH
1,061E-09
D
T
20
10D
CCF
65 ...100
required
B
2 x 10
6
10d
d
(d/a)
365
op
h
(h/d)
24
op
t
(h)
1
cycle
n
8760
op
Diagnostic
60 %
coverage DC
Test interval
according to
1 / year
ISO14119
Category 2: The prerequisites for installation and integration into a
category 2 architecture must be met
Category 3: The prerequisites for installation and integration into a
category 3 architecture must be met
Category 4: The prerequisites for installation and integration into a
category 4 architecture must be met, in particular 2 actua-
tors must be used
PFH
:
A single module has no function. As a result, an individual
D
module cannot have any safety-related characteristic values.
The safety-related characteristic data in the table only serve
to determine the values of a unit into which it is integrated.
When used as part of a key transfer system:
- PFH
total STS system = SUM PFH
D
- Lowest category of a module = category of whole
STS system
- Lowest DC of a module = DC entire STS unit
!
If the design of a unit is changed, the safety-related data may also
change.
Bregstraße 18 • Phone +49 7723 654-0 • Fax +49 7723 654356
8
SAFEMASTER STS Actuator module A / 11.01.21 en / 335A
Actuator module A
3
3
d
e
6,84592E-09 5,4469E-09 1,00122E-10
20
20
85 ...100
85 ...100
2 x 10
6
2 x 10
6
365
365
24
24
1
1
8760
8760
60 %
90 %
1 / year
1 / month
+ ... PFH
D1
4
e
20
85 ...100
2 x 10
6
365
24
1
8760
99 %
1 / month
Dn

Publicité

loading