FR
7. Repair Guide
ES
TROUBLE
PT
Fan will not
start
IT
EL
Fan sounds
PL
noisy
KZ
Mechanical
UA
noise
RO
Fan wobbles
EN
8.Others (Service, Repairing, Guarantee, etc.)
Have your product repaired by a quali ed person.
This electric product is in accordance with the relevant safety requirements.
Repairs should only be carried out by quali ed persons using original spare parts, otherwise This may
result in considerable danger to the user.
Please contact the store which you bought the product for after sale services if any question.
Please contact the store which you bought the product if you lost the installation manual.
5 years guarantee for LED chip only and based on residential usage 8 hours/day for the integrated LED
product.
The light source contained in this luminaire shall only be replaced by the manufacturer or his service
agent or a similar quali ed person.
PROBABLE CAUSE
The fan is under protection.
Fuse or circuit breaker blown.
Loose power line connections to the
fan.
Speed controller not in correct positon.
Top canopy touching ceiling.
Loose fan blades screws.
Ceiling fan not secured against ceiling.
Incorrect speed controller.
Fan blades are not horizontal to ceiling.
Blade screws are loose.
SUGGEST REMEDY
Restart the fan after 10 seconds without power.
Check main and branch circuit fuses or circuit
breakers.
Check line wire connections to fan and wires .
Check speed controller's position.
Lower canopy form ceiling to ensure minimum
3mm clearance.
Re-tighten all screws on fan blades but never
over-tighten.
Re-tighten all screws in the hanging bracket or
plate.
Change the controller to one supplied.
Allow at least for 8 hours setting-in period.
Measure from ceiling to tips of baldes,then
rotate fan so all blades are checked for equal
height from ceiling(not adjustments may be
made by slight pressure up or down on blade
holders).
Make sure all screws are securely fastened.