9. MAINTANCE SCHEDULE
Daily
(8 h)
Every
50 h
Every
100 h
Every
200 h
Every
300 h
Every
500 h
Every
1000 h
(24 months)
NOTE
Maintenance operations require trained and qualified personel.
The maintenance schedule is given as a guide. Under severe conditions, the frequency of
maintenance must be increased.
Initial oil change should be performed after first twenty (20) hours of use. Thereafter change oil every
100 hours. Before changing the oil, check for a suitable way to dispose of the old oil. Do not pour
it down sewage drains, onto garden soil or into open streams. Your local zoning or environmental
regulations will give you more detailed instructions on proper disposal.
10. ''HOW-TO'' MAINTENANCE
10.1. ENGINE OIL CHANGE
Change engine oil every 100 hours. (For new engine, change oil after 20 hours). Fig.
1.
Drain oil by removing the drain plug and the oil filler cap while the engine is warm.
Check all components according to ''PRE-OPERATING CHECKS''.
Check and refill gasoline and engine oil.
Wash air cleaner foam element more often if used in dirty or dusty
environments.
Check the condition of the paper element. Do not wash the paper element.
Change oil more often if used in dusty or dirty environment.
Check the spark plug and clean it if necessary.
Replace air cleaner element.
Clean fuel strainer.
Clean and adjust spark plug gap.
Change oil more often if used in dusty or dirty environnement
Check and adjust valve clearance.
Remove carbon from cylinder head and the top of the cylinder.
Clean and adjust carburetor.
Replace engine mount rubber.
Inspect control panel parts.
Check rotor and stator.
Replace engine mount rubber.
Overhaul engine.