Dear customer,
thank you for purchasing this product. We would like to ask you to read the following notes and tips so that
you can enjoy this product for a long time.
Checking the product:
Check your Shower-Set prior to installation for transport damage or other damage that may have occurred.
After the installation of the product no claims for damages will be accepted under the warranty.
Chrome surfaces have certain manufacturing characteristics. These may be hairline scratches or irregularities
in the metal. There should be no cause for concern if you cannot see any such imperfections when standing
at a distance of 1,5 metres from the object and under normal lighting conditions. The overall impressions is
conclusive.
Technical Construction Requirements:
Scope of use:
This product is intended for connection to a pressurized hot water supply. When used in conjunction with
water heaters it needs to be taken care of sufficient performance of at least 24kW.
The product is not suitable for use with non-pressurized storage (open water systems).
The product is factory-adjusted to a flow pressure of 3 bar with a flow temperature of 60°C.
For different installation conditions, adjusting the thermostat may be required.
Refer to Maintenance section!
Technical data:
min. flow pressure:
max. operating pressure:
Operating pressure greater than 5 bar = pressure reducer required.
max. flow temperature:
rec. flow temperatu:re
The flow temperature must be at least 5°C higher than the mixed water temperature.
Flow rate at 3 bar pressure at hand / and shower head (standard version): 9 l/min
The valve must be drained separately in case of frost. Emptying of water pipe network is not sufficient.
Mounting:
Flush before and rinse after installation according to EN 806 (run at main tap about 3 min. open water).
Connection to wall plates with G1/2, hole centres 150mm, hot water left, cold water right.
1 bar
5 bar
80°C
60°C