CFM Reduction System
Before operating your hood:
Some States and Provinces of the US & Canada restrict the
maximum exhausting airflow of range hoods.
Airflow is measured as cubic feet per minute (CFM).
These maximum levels allowed are detailed in the local code
of your area. Please check local codes to find out if you need
to restrict the maximum airflow of your hood. If your local
code mandates a maximum airflow level below the maximum
airflow of this hood (i.e. 430 CFM), please execute the procedure
below to reduce the maximum airflow.
1
Maintenance
Cleaning
Do not spray cleaners directly to the control while cleaning the
Hood. The cooker hood should be cleaned regularly (at least
with the same frequency with which you carry out maintenance
of the fat filters) internally and externally. Clean using the
cloth dampened with neutral liquid detergent. Do not use
abrasive products.
DO NOT USE ALCOHOL!
I
WARNING:
Failure to carry out the basic cleaning recommendations of the
cooker hood and replacement of the filters may cause fire risks.
Therefore, we recommend oserving these instructions.
The manufacturer declines all responsibility for any damage to
the motor or any fire damage linked to inappropriate maintenance
or failure to observe the above safety recommendations.
Metal grease filter
The filters should be washed frequently. Place metal filters in
dishwasher or hot detergent solution to clean. Let filter dry
thoroughly before replacing it.
Turn off fan and lights. Allow lamps to cool.
1
Remove each filter by pushing down the spring release
handle and then pulling down the filter.
2
Wash metal filters as needed in dishwasher or hot
detergent solution.
3
Reinstall the filter by making sure the spring release
handles are toward the front. Insert metal grease filter into
upper track.
4
Pull the spring release handle down.
5
Push up on metal filter and release handle to latch into
place.
6
Repeat steps 1-5 for the other filter.
Replacing a LED lamp
The LED lights are replaceable by a service technician only.
See "Who to contact" section in the warranty for service
contact information.
Charcoal filter
If the model is not vented to the outside, the air will be
recirculated through disposable charcoal filters that help
remove smoke and odors.
The charcoal filters cannot be cleaned.
10
1
Turn the motor OFF.
2
Press the ON/OFF (1) and Intensive speed (5) buttons
together for 3 seconds.
You will hear a beep and all control lights will illuminate
for 3 seconds.
This action will Disable speeds 3 and 4 and effectively
lower the Maximum airflow to >300 CFM.
3
Locate the CFM certification sticker in the hardware pack.
4
Peel and Affix this sticker to a visible area in the blower.
This sticker provides official certification to your local
5
inspector that this hoods maximum airflow has been
reduced to >300 CFM.
They must be replaced.
The charcoal filters are clipped inside of each metal grease
filter (mounting instructions included with charcoal filters kit).
The charcoal filters should be replaced every 4-6 months
(depending on hood usage).
NOTE: DO NOT rinse, or put charcoal filters in an automatic
dishwasher.
NOTE: Charcoal filters are not included with the hood.
They must be ordered from your supplier.
Order the needed kit specifying your hood model and width
size.
Charcoal filter placement (Recirculating accessories)
Fit the charcoal filter mattress on the upper side of each
grease filter.
Use provided springs to fix it in place.
NOTE: When removing or replacing the filters, do not remove
the Fixing Springs, simply rotate them upward 90 degrees.
This will allow you to remove or rotate the filter.
Fixing spring
Charcoal filter
Grease filter
top side