Fresh Air Ventilation Switch
(open for Fan only operation)
Interior air
outlet
Interior air
inlet
Control
Panel
ELECTRICAL
SPECIFICATIONS
1) All wiring must comply with local and national electrical
codes and must be installed by a qualified electrician. If you
have any questions regarding the following instructions,
contact a qualified electrician.
2) Check available power supply and resolve any wiring
problems BEFORE installing and operating this unit.
3) This 115V air conditioner uses 10 or less nameplate amps
and may be used in any properly wired, general purpose
household receptacle. See Table 1 for specifications for
individual branch circuit.
4) For your safety and protection, this unit is grounded
through the power cord plug when plugged into a matching
wall outlet. If you are not sure whether your wall outlet is
properly grounded, please consult a qualified electrician.
5) The wall outlet must match the 3-prong plug on the service
cord supplied with the unit. DO NOT use plug adapters. See
Table 2 for receptacle and fuse information. If it is necessary
to use an extension cord to connect your air conditioner, use
an approved "air conditioner" extension cord only
(available at most local hardware stores).
6) The rating plate on the unit contains electrical and other
technical data. The rating plate is located on the right side of
the unit, above the power cord.
PART IDENTIFICATION
IMPORTANT SAFETY INFORMATION
READ ALL SAFETY INFORMATION BEFORE USING
Cabinet
Suggested Individual Branch Circuit
Nameplate Amps
4.9 to 10
AWG- American Wire Gauge
*Based on copper wire at 60°C temperature rating.
Receptacle and Fuse Types
Rated Volts
Amps
Wall Outlet
Fuse Size
Time Delay Fuse
(or Circuit Breaker)
2
Exterior air
inlet
Filter
TABLE 1
*AWG Wire Size
14
TABLE 2
125
15
15
Plug Type