4.3
hard-wiring installation
WARNING
!
•
Turn off the appliance completely and let cool before servicing. Only a qualified service person should service
and repair this electric appliance.
HARD-WIRING CONNECTION
If it is necessary to hard-wire this appliance, a qualified electrician must remove the cord connection, and wire the
appliance directly to the household wiring. The wire and power supply breaker must be rated for 120V, minimum
15 amps.
This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local
codes, with the latest edition of the National Electrical Code ANSI/NFPA 70 in the United States or the Canadian
Electrical Code CSA C22.1 in Canada.
4.3.1 120V hard-wiring installation
1. Remove the 4 screws securing the cord and cover plate to the side of the firebox.
2. Unscrew the wire nuts securing the power supply cord.
3. Install the new strain relief (supplied) (Fig. 4-1) into the new cover plate (supplied) and feed the 14/2
conductor wire through the strain relief.
4. Connect the ground/bond wires together.
5. Connect L1 to L1 of the appliance.
6. Connect the supply N wire to the two N wires in the junction box. Do not connect the L2 wire.
7. With wires secured, carefully feed the wires into the firebox and re-secure the cover plate.
B x 1
APPLIANCE WIRE
A
APPLIANCE WIRE
HARNAIS DE FIL
D'APPAREIL
C x 1
120V Wiring
4.3.2 240V hard-wiring installation
1. Remove the 4 screws securing the cord and cover plate to the side of the firebox.
2. Unscrew the wire nuts securing the power supply cord and the L2 wire.
3. Install the new strain relief (supplied) (Fig. 4-2) into the new cover plate (supplied) and feed the 14/3
conductor wire through the strain relief.
4. Connect the ground/bond wires together.
5. Connect L1 to L1 of the appliance, connect the supply N wire to the single white N wire in the firebox.
Connect the L2 wire to the L2 wire of the appliance.
6. Screw the wire nuts onto the blue N wire. Do not connect supply wires to this wire.
7. With wires secured, carefully feed the wires into the firebox and re-secure the cover plate.
A
B x 1
D x 1
APPLIANCE WIRE
C x 1
240V Wiring
MATERIAL: CLASS IIA-1 PERMANENT LEXAN ADHESIVE LABEL, MINIMUM THICKNESS 0.1MM, TEMPERATURE
RATING MINIMUM OF 121°C (250°F)
SPECIFICATION: BLACK LETTERING ON WHITE BACKGROUND
LABEL SIZE: 5 1/4" (133mm) x 2 5/16" (59mm)
TITLE: LABEL, 120V HARD-WIRING (NEFB36H-BS)
120V Hard-Wiring
Branchment par Câble 120V
Branchment par Câble 120V
BLACK / NOIR
RED / ROUGE
HARNESS
HARNESS
WHITE / BLANC
BLUE / BLEU
YELLOW & GREEN
JAUNE & VERT
240V Hard-Wiring
Branchment par Câble 240V
Branchment par Câble 240V
BLACK / NOIR
RED / ROUGE
APPLIANCE WIRE
E
HARNESS
HARNAIS DE FIL
D'APPAREIL
WHITE / BLANC
BLUE / BLEU
HARNESS
YELLOW & GREEN
JAUNE & VERT
electrical information
Junction Box
Cover Plate
HOME POWER
HOME POWER SUPPLY
120VAC
SUPPLY 120VAC
SOURCE
SOURCE
D'ALIMENTATION DE
MAISON 120VAC
Appliance
W385-2371 / A
Junction Box
Cover Plate
HOME POWER
SUPPLY 120VAC
SOURCE
H
HOME POWER
SU
SUPPLY 240VAC
SOURCE
D'ALIMENTATION DE
D'AL
MAISON 240VAC
MA
W385-2372 / A
W
W415-3155 / B / 07.06.23
PART #: W385-2371
EN
Strain Relief
Inside
Outside
Appliance
Fig. 4-1
Strain Relief
Inside
Outside
Appliance
Appliance
Fig. 4-2