Type of lubrification
Hot engine oil pressure
Oil cooling
Oil change
ATTENZIONE - WARNING
SOSTITUIRE OLIO OGNI 500 ORE
CHANGE OIL EVERY 500 HOURS
IMPORTANT
Engines provided with oil sump with a
maximum capacity of 11,5 kg have a la-
bel on the top of the engine that shows
the oil change interval every 500 hours.
English
Lubrification circuit
-
forced lubrification with rotor pump
The engine oil must have the following characteristics:
- Viscosity grade SAE 10W-40
- Oil quality standard: ACEA E6 + E9 or
E8 + E11, API CJ4 / CK4.
- TBN (Total Base Number) ≥ 10mgKOH/g.
- Lubricants recommended for ambient temperatures from
-20°C (-4°F) to +50°C (+122°F):
-
Petronas Urania 5000 LS 10W-40
Motorex Focus QTM 10W-40
In case of lower ambient temperatures (down to -30°C) it's
allowed to use an engine oil with the above specifications
SAE 5W-40 or SAE 5W-30.
Do not mix oils with different characteristics
bar
3,0 - 6,5 between minimum and maximum engine speed
-
engine oil sump without balance shaft 300 hours / 8.7 Kg
engine oil sump with balance shaft 300 hours / 7.4 Kg
(kg)
engine oil sump without balance shaft 500 hours /11,5 kg
engine oil sump with balance shaft 500 hours /10,7 kg
15
- Full or semi-synthetic.
or:
and the following grade:
Oil/water cooler
R754EU6C
GB
42432104F