Troubleshooting
If your appliance develops a fault, please check the following table before making a call to the Helpline.
Fault
The appliance is not
The unit is not switched on
working
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
The appliance turns
Condenser blocked with dust
on, but the
Doors are not shut properly
temperature is too
Appliance is located near a heat source
high/low
or air flow to the condenser is being
interrupted
Ambient temperature is too high
Insufficient airflow to the fans
Appliance is overloaded
Factory default parameters adjusted
The appliance is
The appliance is touching a neighbouring
unusually loud
object
The appliance has not been installed in a
level or stable position
Technical Specifications
Model
Voltage
CB929
230V 50Hz
CB930
230V 50Hz
CB931
230V 50Hz
CB932
230V 50Hz
CC601
230V 50Hz
CC605
230V 50Hz
CD089
230V 50Hz
CE205
230V 50Hz
CE206
230V 50Hz
CE207
230V 50Hz
CF759
230V 50Hz
GH132
230V 50Hz
GH133
230V 50Hz
GH134
230V 50Hz
DP286
230V 50Hz
DP287
230V 50Hz
GJ447
230V 50Hz
Probable Cause
Temperature
Power
Current
Range
160W
1.1A
2°C to 8°C
280W
1.8A
2°C to 8°C
280W
1.8A
2°C to 8°C
315W
1.9A
2°C to 8°C
280W
1.8A
2°C to 8°C
315W
1.9A
2°C to 8°C
160W
1.1A
2°C to 8°C
160W
1.1A
2°C to 8°C
280W
1.8A
2°C to 8°C
315W
1.9A
2°C to 8°C
280W
1.8A
2°C to 8°C
160W
1.1A
2°C to 8°C
280W
1.8A
2°C to 8°C
315W
1.9A
2°C to 8°C
160W
1.1A
2°C to 8°C
280W
1.8A
2°C to 8°C
300W
1.2A
2°C to 8°C
Check the unit is plugged in correctly and switched on
Call POLAR agent or qualified Technician
Replace the fuse
Check power supply
Call POLAR agent or qualified Technician
Clean Condenser
Check doors are shut and seals are not damaged
Move the appliance to a more suitable location
Increase ventilation or move appliance to a cooler
position
Remove any blockages to the fans
Reduce the amount stored in the appliance
Call POLAR agent or qualified Technician
Check installation position and change if necessary
Check installation position and change if necessary
Capacity
Refrigerant
(litres)
140
R134a 140g
223
R134a 140g
223
R134a 140g
335
R134a 150g
223
R134a 140g
335
R134a 150g
140
R134a 140g
140
R134a 140g
223
R134a 140g
335
R134a 150g
223
R134a 140g
140
R134a 140g
223
R134a 140g
335
R134a 150g
140
R134a 140g
223
R134a 140g
307
R134a 180g
UK
Action
Dimensions
Weight
H x W x D (mm)
(kg)
925 x 600 x 540
54
925 x 920 x 540
75
925 x 920 x 535
72
925 x 1350 x 540
95
925 x 920 x 535
95
925 x 1350 x 535
91
925 x 600 x 535
54
925 x 600 x 540
54
925 x 920 x 540
75
925 x 1350 x 540
95
870 x 920 x 535
62
925 x 600 x 540
54
925 x 920 x 540
75
925 x 1350 x 540
95
870 x 600 x 540
54
870 x 920 x 540
75
1880 x 600 x 514
112

Publicité