FLOOR PROTECTION
This heater must have a non-combustible floor protector (ember protection) installed beneath it if the floor is
of combustible material. If a floor pad is used, it should be UL listed or equal. The floor pad or non-combustible
surface should be large enough to cover at least the area under the product and 6 in. (152 mm) beyond the front
and beyond each side of the fuel loading and ash removal openings. Floor protection must extend under and 2 in.
(50.8mm) to each side of the chimney tee for an interior vertical installation (see FIGURE 2).
Canadian Installations require a minimum of 450 mm [17.7"] beyond the front of the unit and 200mm [7.8"]
beyond each side of the unit. A Floor Protector of ¼ inch thick is recommended for this installation.
Through the wall installation
Installation
FIGURE 1
Interior vertical installation
-5-
FIGURE 2