8 | English
Charger
– 5.0 Ah
– 6.0 Ah
Number of battery cells
Weight according to
EPTA-Procedure 01:2014
Protection class
Operation
Start-up
Note the mains voltage! The voltage of the power source
u
must match the voltage specified on the rating plate of
the charger. Chargers marked with 230 V can also be op-
erated with 220 V.
Charging process
The charging process begins as soon as the mains plug for
the charger is inserted into the mains socket and the battery
(1) is inserted into the charging slot (2).
Thanks to the intelligent charging process, the charge condi-
tion of the battery is automatically detected and then
charged up with the optimal charge current depending on
battery temperature and voltage.
In this way, the battery is treated with care and remains per-
manently fully charged when it is stored in the charger.
What the display elements mean
Flashing green battery charge level indicator (4)
The rapid-charging procedure is indicated by
flashing of the green battery charge level in-
dicator (4). The battery can be removed at any
time and used.
Note: The charging process is only possible when the tem-
perature of the battery is within the permitted charging tem-
perature range, see section "Technical data".
Once approx. 80% of the battery capacity has
been reached, the flashing of the green battery
80 %
charge indicator slows down. The rapid-char-
ging process is now completed. If the battery
remains in the charger, the charging process
will be completed in the Long Life charging mode.
Continuously illuminated green battery charge level
indicator (4)
The continuous light of the green battery
charge level indicator (4) signals that the bat-
tery is fully charged.
The battery can then be removed for immediate use.
When there is no battery connected, the continuous light of
the battery charge level indicator (4) indicates that the
mains plug is plugged into the mains socket and that the
charger is ready to be used.
1 609 92A 4ET | (31.07.2018)
Continuously illuminated red battery charge level
GAL 18V-40
indicator (3)
min
(60)/70
min
(72)/95
3-15
kg
0.55
data". The charging process begins as soon as the permitted
temperature range has been reached.
/ II
Flashing red battery charge level indicator (3)
ive measures".

Wall mounting

The charger can be used either free-standing (for use on a
desktop) or mounted on the wall.
When affixing to the wall: Drill two holes, leaving a clearance
as specified in the image.
To secure it, use round-head screws with a diameter of 5 mm
to max. 6.5 mm.
Errors – Causes and Corrective Measures
Cause
Red battery charge level indicator (3) is flashing
Charging not possible
The battery is not connected
(correctly)
Battery contacts are dirty
Battery defective
Green battery charge level indicator (4)/Red battery
charge level indicator (3) is not illuminated
The continuous light of the red battery charge
level indicator (3) shows that the temperature
of the battery is outside of the permitted char-
ging temperature range, see section "Technical
The flashing light of the red battery charge
level indicator (3) signals that the charging
process has been interrupted by a different
fault, see section "Errors – causes and correct-
72 mm
Corrective measures
Connect battery to charger
correctly
Clean battery contacts; e.g.
by connecting and discon-
necting the battery several
times. Replace battery if ne-
cessary
Replace battery
Bosch Power Tools