Copyright
© Copyright 2013, Desoutter HP2 7SJ UK. All rights reserved.
Any unauthorized use or copying of the contents or part thereof
is prohibited. This applies in particular to trademarks, model
denominations, part numbers and drawings. Use only authorized
parts. Any damage or malfunction caused by the use of
unauthorized parts is not covered by Warranty or Product
Liability.
Statement of use
This product is designed for installing and removing threaded
fasteners in wood, metal and plastic. No other use permitted. For
professional use only. The use of spare parts/accessories other than
those originally supplied by the manufacturer may result in a drop
in performance and/or increased maintenance/noise
level/vibrations, and as the result, the full cancellation of the
manufacturer's liability.
Installation
Air quality
– For optimum performance and maximum machine life we re-
commend use of compressed air with a dew point between
+2°C and +10°C. Installation of a refrigeration-type air dryer
is recommended.
– Use a separate air filter to remove solid particles larger than
30 microns and more than 90 % of water, installed as close as
possible to the machine and prior to any other air preparation
unit. Blow out the hose before connecting.
– The compressed air must contain a small quantity of oil. We
strongly recommend that you install a oil-fog lubricator to be
set normally at 3-4 drops(50mm
cycle running tools, or a single-point lubricator for short cycle
running tools.
– Regarding lubrication free tools it is, at the customers option,
no disadvantage if the compressed air contains a small quantity
of oil as supplied from a lubricator. An exception is turbine
tools that should be kept oil free. (For further information please
see Air Line Accessories in our main catalogue.)
Compressed air connection
– The machine is designed for a working pressure of 6–7 bar =
600–700 kPa = 87–102 psi.
– Blow out the hose before connecting.
Handling
Setting of tightening torque
A
The adjusting screw is accessible through the hole in the
housing. If necessary, turn the outgoing spindle.
After adjusting, do not forget to assemble the plug of the hole in
the housing.
It is recommended to start at min. torque setting - when the ad-
justment screw is screwed out approx. 6 turns from the bottom
position. Do not screw out more.
Use of a machine over recommended maximum torque might
result in improper function and faster wear.
Always check the setting on your actual joint.
3
3
)/m
air consumption for long
EN
Test method - Static or Dynamic
A static torque measurement is recommended for the Pulse Tool
machines.
If dynamic torque measurement with an electronic inline torque
transducer is used, always verify your measurement result by a
static check with a torque wrench (electronic).
NEVER CONNECT A PART ASSEMBLED TOOL
TO THE AIR SUPPLY. THE ROTOR BLADES IN
THIS TOOL HAVE A PTFE CONTENT. THE NOR-
MAL HEALTH AND SAFETY RECOMMENDA-
TIONS CONCERNING PTFE MUST BE OB-
SERVED WHEN HANDLING THESE ROTOR
BLADES.
– DO NOT SMOKE.
– MOTOR COMPONENTS MUST BE
WASHED WITH CLEANING FLUID
AND NOT BLOWN CLEAR WITH AN
AIR LINE.
– THE SILENCER MUST BE REPLACED
WHEN DIRTY, DO NOT CLEAN AND
RE-USE.
– WASH HANDS BEFORE COMMEN-
CING ANY OTHER ACTIVITY
Maintenance
– All torque figures ± 10%.
– When disposing of components, lubricants, etc. ensure that the
relevant safety procedures are carried out.
– Overmold should be wiped clean with a general purpose,
nonaggressive degreasant.
For maximum performance
At tough working conditions – soft joints and max. setting – lub-
rication of the air is recommended.
With extreme dry air the service life of vanes and machine per-
formance might be reduced. A daily supply of 0.1 – 0.2 ml oil into
the machine inlet will improve the machine performance. At hard
joints and low tightening torque settings reduced free speed by the
Trim-valve will improve the accuracy. Alternatively consider an
automatic lubricator device, oil fog lubricator or single point lub-
ricator which will improve the machine performance.
Refill the pulse-unit with oil
For further information pls see - Service Instructions.
For optimum machine performance the pulse unit must be cor-
rectly filled with oil. Due to a possible microleakage of oil from
the pulse unit, it could be necessary to refill the unit between the
regular overhaul intervals. The frequency of this procedure depends
on the type of application, number of cycles, tightening time etc.
An accurate refill of the pulse unit gives long service intervals.
Too much oil in the pulse unit implies a low pulse frequency
and slow tightening.
Too little oil in the pulse unit implies a high pulse frequency
and there will be a risk of a decreasing tightening torque. In partic-
ular at the first tightening after a break the machine might race.
Use Hydraulic Oil : 22 cST / 40 °C (ISO VG22). Running the
machine with too little oil may damage the pulse unit. After the
refill – Check the tightening torque, see Service instructions.
Rust protection and internal cleaning
Water in the compressed air, dust and wear particles cause rust
and sticking of vanes, valves etc. An air filter should be installed
Part no
2050505713
Issue no
4
Series no
C
Date
2015-03
Page
3
WARNING