Assembly
WARNING:
When assembling or inserting the extraction filter
as well as the carbon filter, the appliance must not
be connected to the mains.
Failure to use the mounting fixtures may lead to a
risk of electric shock.
CAUTION:
Before mounting, check that the wall has enough
load capacity to bear the cooker hood.
When drilling the holes in the wall always make
sure that no existing electrical cables or other ob-
jects are damaged.
Make sure that the ventilation slots are clear of
obstacles and are not covered.
NOTE: Recommendations for preparation work
When installing, ask another person to assist.
Wear protective gloves to prevent injuries from
any sharp edges.
Drilling dimensions
Fig. 1
unit mm
A Shaft closure bracket
B Shaft middle bracket
Fig. 2
Fig. 3
Fig. 5
Determine the position of the cooker hood central-
ly above the cooking area in accordance with the
specified safety distances.
Totally 8x mounting holes with a diameter of approx.
8 mm are necessary for the wall mounting. Insert the
supplied dowels [Fig. 1].
First, drill the holes for attaching the housing ac-
cording to the enclosed drilling template. Check
the markings with a spirit level!
Turn in the lower screws 2x ST4*30mm for the
-
suspension of the housing (D) so far that they
project approx. 2~4 mm out of the wall.
Before attaching the housing, insert the non-
return valves by lightly bending them from above
into the connecting piece (extraction duct) [Fig. 2].
44
C Securing housing
D Suspension housing
Fig. 2a
Fig. 4
Fig. 6