2.
Connect neutral ground wire
and neutral wire
E
C
Connect neutral ground wire (E) and neutral wire (white or
center wire) (C) of power supply cord or cable under center
terminal block screw (B). Tighten screw.
3.
Connect remaining wires
Place hooked ends of remaining wires under outer terminal
block screws (hooks facing right). Tighten screws.
4.
Connect external ground wire
E
Connect a separate copper ground wire (E) from the external
ground conductor screw (A) to an adequate ground. Finally,
reinstall terminal block cover. Secure cover with hold-down
screw. Now, go to "Venting Requirements."
16
MAKE GAS CONNECTION –
U.S.A. AND CANADA
1.
Connect gas supply to dryer
Flared
B
male fitting
Remove red cap from gas pipe. Using a wrench to tighten,
connect gas supply to dryer. Use pipe-joint compound
on threads of all non-flared male fittings. If flexible metal
tubing is used, be sure there are no kinks.
NOTE: For propane gas connections, you must use pipe-joint
compound resistant to action of propane gas. Do not use
TEFLON
tape.
®
2.
Plan pipe fitting connection
A. 3/8" flexible gas connector
B. 3/8" dryer pipe
A combination of pipe fittings must be used to connect dryer
to existing gas line. A recommended connection is shown. Your
connection may be different, according to supply line type,
size, and location.
A
3.
Open shut-off valve
Closed valve
A
Open shut-off valve in supply line; valve is open when handle
is parallel to gas pipe. Then, test all connections by brushing
on an approved noncorrosive leak-detection solution. Bubbles
will show a leak. Correct any leaks found.
Non-flared
male fitting
B
D
C
C. 3/8" to 3/8" pipe elbow
D. 3/8" pipe-to-flare adapter fitting
B Open valve
A
B