8.5. Trouble shooting and remedy
If errors or problems occur that are not described, contact the local service technician for assistance.
Fault
The unit does not
•
No supply voltage to the unit
start
•
Error message in display
•
Flow switch out of adjustment
No pressure /
•
Insufficient water supply at unit
too low pressure
•
Filter is clogged
•
The pump is leaking or making jarring
sounds
•
Rinsing nozzle not installed
•
No water supply
Insufficient foam
•
Product not suitable
creation
•
Insufficient air supply at unit
•
Air pressure in mixing chamber too high
•
Defect non-return valve for air
•
Incorrect nozzle
•
Leaking or blocked product non-return
valve
•
System needs deliming
No foam
•
Product not suitable
creation
•
Air pressure in mixing chamber too high
•
Defect non-return valve for air
•
No air supply at unit
•
Non-return valve blocked
•
Nozzle of mixing chamber blocked
•
Leaking or blocked product non-return
valve
•
System needs deliming
No spray
•
Non-return valve blocked
sanitising
•
Nozzle of mixing chamber blocked
•
Leaking or blocked product non-return
valve
•
System needs deliming
Cause
Remedy
• Make sure that power supply and inverter are
switched on.
• Read error and act accordingly
• Try to readjust flow switch
• Open water supply valve
• Clean the filter
• Call technician
• Place rinsing nozzle
• Ensure water supply
• Choose suitable product
• Provide sufficient air supply
• Adjust air pressure setting
• Replace non-return valve for air
• Place foam nozzle 50/200
• Clean or replace product non-return valve
• Delime the unit according to section 8.4.3.
• Choose suitable product
• Adjust air pressure setting
• Replace non-return valve for air
• Ensure air supply
• Clean or replace non-return valve
• Clean nozzle
• Clean or replace product non-return valve
• Delime the unit according to section 8.4.3.
• Clean or replace non-return valve
• Clean nozzle
• Clean or replace product non-return valve
• Delime the unit according to section 8.4.3.