Télécharger Imprimer la page

Ecolab MH42 Mode D'emploi page 40

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 76
CAUTION
The product supply must always be
rinsed thoroughly after use.
For instructions on rinsing product supply, refer
to Section 8.4.1.
4.3. Emergency shutdown
4.3.1. Turn off the power supply
Turn off the power supply to the unit.
Turn off the inverter. The inverter can be shut
down by turning the button to a vertical position
(refer to image below).
4.3.2. Closing valve for water supply.
With this valve the unit can be isolated from the
water supply.
A non-return valve is built into the unit to prevent
water backflow.
Open
4.3.3. Closing valve for air supply (MH42 / MP42)
This valve can isolate the unit from the water sup-
A
B
ply.
Non-return valves are built into the unit to prevent
air backflow.
37
DANGER:
In case of error/defect or service
on equipment:
1. Turn of power supply.
2. Close the water supply.
A
3. Close the air supply.
110009367
110009214
Closed
110009224
Open
4.4. Noise
B
Sound level according to ISO 11202: Below 70dB.
4.5. Vibrations
Hand-arm vibrations according to ISO 5349-1.
4.6. Anticipated failures and precautions
4.6.1. Bursted air tube in unit (MH42 / MP42):
Ensure front cover is mounted and air valve is
closed when not in use.
Regularly inspect air hoses and fittings and re-
place if damaged.
4.6.2. Breakdown of non-return valves for air and
water:
Unit cover must be mounted during use.
Close air and water valves when not in use.
Rinse all product non-return valves after use
(refer to section 8.4.1.)
Examine air and water non-return valves once a
year by authorized personnel.
4.7. Residual risk
4.7.1. Damaged unit:
Do not use if isolation valves cannot be operated
or required operation cannot be selected.
Never use the unit if it has been dislodged from
its original place of mounting.
4.7.2. Repair of unit:
Do not attempt to repair a unit by yourself. Always
contact an authorized service company. Refer to
the back of the manual for service addresses.
Block and mark any defect unit in order to avoid
unintended use.
For safety reasons only use approved and origi-
nal spare parts.
110009224
Closed

Publicité

loading

Ce manuel est également adapté pour:

Mp42Bh4Bp4Bh7