Télécharger Imprimer la page

Ecolab MH42 Mode D'emploi page 37

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 76
3.5. Technical Specifications
Technical data
General
Sound level ISO 11202
Dimensions HxWxD
Weight
IP class
Water
Max. outlet pressure
Operational flow range
Min. supply pressure
Max. supply pressure
Min. water supply
Max. water temperature
Pipe dimension inlet Ø
Pipe dimension outlet Ø
Clamp connection (ferrule)
Electricity
Supply voltage
Frequency
Motor load
Max. total load
Nominal current
Fuse
Electrical cable; L1 L2, L3, PE (min)
Output ratings:
Max. load single output
Max. load sum of all outputs
Voltage nom.
Voltage min.
Voltage max.
Input ratings:
Input voltage on
Min. input voltage on
Max. input voltage on
Max. input voltage off
Air
Min/max air pressure
Compressed air consumption
Pipe dimension inlet Ø
Units
dB
mm
1260x550x392
[inches]
[49x22x15]
kg
[lbs]
MPa
2+inlet max 2.5
(bar)
(20+inlet max 25)
[psi]
[290+inlet max 362]
L/min
[gal/min]
MPa
(bar)
[psi]
MPa
(bar)
[psi]
L/min [gal/min]
120 [31.7]
C° [°F]
mm
["]
mm
["]
CLAMP FERRULE DIN 32676 Ø50,5
V
3/PE 380-528 Vac
Hz
kW
kW
A
A
mm
2
A
A
V
V
V
V
V
V
V
MPa/(bar)/[psi]
0.6-1/(6-10)/[87-145]
l/min/ [gal/min]
200/[53]
mm
MH42
<70
112
[246]
55
2+inlet max 2.5
(20+inlet max 25)
[290+inlet max 362]
10-120
[2.6-31.7]
0.2
(2)
[29]
0.8
(8)
[116]
70 [158]
38 [1.49]
38 [1.49]
CLAMP FERRULE DIN 32676 Ø50,5
3/PE 380-528 Vac
50/60
5.5
6
14.2
20
4 x 2.5
0.8
2
24
22
24.5
24
22
25
2
0.6-1/(6-10)/[87-145]
6
MP42
<70
1260x550x392
[49x22x15]
96
[211]
55
10-120
[2.6-31.7]
0.2
(2)
[29]
0.8
(8)
[116]
120 [31.7]
70 [158]
38 [1.49]
38 [1.49]
50/60
5.5
6
14.2
20
4 x 2.5
200 /[53]
6
34

Publicité

loading

Ce manuel est également adapté pour:

Mp42Bh4Bp4Bh7