Télécharger Imprimer la page

marklin 74465 Mode D'emploi page 10

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
CV Programming
CV programming must be done on the programming track.
We recommend creating a fictitious locomotive for programming
purposes. Values in parentheses are the factory settings.
The turnout lantern connected to the digital installation decoder
will blink as a control check during the data transmission.
fx (MM)
Before doing any programming, the turnout to be programmed
must be switched with the Keyboard. After that the CVs are
changed immediately with the Control Unit or the CV configura-
tion on the Central Station. After that the programmed turnout
is to be switched again with the Keyboard. At this point the
programming is accepted and is functional.
CV Meaning
8
Decoder reset
34 Three-way turnout 0-1 (1) Setting for the Central
36 Turnout lantern
off/on
The procedure for programming with the 6021 Control Unit is the
same as locomotive programming (www.maerklin.de -> Tools &
Downloads -> Technische Informationen).
10
Values
8
(-) factory setting, not written
value is
Station 60213/214/215
always 0
Setting for other controllers
always 1
0-1 (1)
DCC
CV Meaning
1 Address, lower value Byte 0-255 (1)
7 Manufacturer version
number (software
version)
8 Manufacture recognition
ID Decoder reset
9 Address, higher value
Byte
29 Configuration
Bits 0-4 are not used
Bit 5: Decoder type
Bit 6: Addressing method
Bit 7: Decoder type
34 Three-way turnout
36 Turnout lantern, off/on
Setting and generating addresses larger than 255:
Example: Address 1044 -> 1044:256=4,078125. The value before
the comma (4) is to be entered in CV 9. The value after the
c omma (0,078125) is multiplied by 256, 078125x256=20. The value
of 20 that is generated must be entered in CV 1.
Values
(-) read only
(131)
read only,
8
(-)
factory setting, value
is not written
0-7
(0)
(192) read only
0
0 / 32 basic or advanced
accessory decoder
decoder or output
0 / 64
address
128 accessory decoder
0-1
(1) Setting for the
Central Station
60213/214/215
always 0
Setting for other
controllers always 1
0-1
(1)

Publicité

loading