INSTALL THE HOUSING
(continued)
Existing Construction
4. Place housing in opening so that its bottom edge is flush
with finished ceiling. Nail to joist through keyhole on both
sides. To ensure a noise-free installation, drive another nail
through the top hole of each mounting bracket.
5. Additional mounting holes are provided for installations
where access from above is inconvenient or not possible.
Nail or screw housing directly to joists or framing.
INSTALL THE DUCTWORK
NOTE: The duct connec-
tor has a counter-balanced
damper flap. The flap will be
"open" approx. 1" when duct connector is attached to housing.
This design permits insulation to be in direct contact with fan/
light housing per UL (Underwriters Laboratories) standards.
The slightest backdraft, however, will close the damper flap,
preventing air from entering unit or finished space.
1. Snap the damper/duct connector onto housing. Make sure
that tabs on the connector lock into slots in housing. Top of
damper/duct connector should be flush with top of housing.
2. Connect 4" round duct to damper/duct connector and
extend duct to outside through a roof or wall cap. Check
damper to make sure that it opens freely. Tape all duct
connections to make them secure and air tight.
ADDITIONAL
MOUNTING
HOLES
FLUSH
MODELS 764BN • 764RB • 764WH
CONNECT THE WIRING
SCHEMATIC WIRING DIAGRAM
L I G H T
S W I T C H
V E N T
S W I T C H
B L K
L I N E
W H T
I N
G R D
S W I T C H B O X
BLACK
WHITE
BLUE
DUAL CONTROL
(purchase separately)
SWITCH BOX
LIGHT
FAN
120 VAC
LINE IN
allow cable to touch sides or top of unit after installation is
complete.
ATTACH THE GRILLE PAN AND
GLASS SHADE
1. Locate the grille pan
over the fan housing
and connect the wiring
harness plug into white
receptacle in the fan
housing.
2. Insert rod through center
hole of grille pan. Use
washer between collar
on rod and pan.
3. Thread rod onto grille
screw in housing, until
pan is tight against
ceiling. Do not over-
tighten mounting rod.
4. Install bulbs. Use 60-
watt (maximum), B10
type, candelabra bulbs.
5. Place washer and glass
shade over mounting
rod and align shade
onto grille pan. Secure
glass shade to grille pan
with finial cap and nut as
shown.
6. Restore electrical power
and check operation of
the unit.
R E D
B L U
W H T
L I G H T
( W H I T E )
B L K
B L K
W H T
V E N T
( B L A C K )
W H T
G R D
U N I T
WHITE
RED
RECEPTACLE
(LIGHT)
GROUND
(bare)
WIRING
PLATE
1. Wire unit following diagram
above. Run electrical cable as
direct as possible to unit. Do not
GRILLE
PAN
WASHER
ROD
GLASS SHADE
FINIAL
NUT
CANDELABRA
GRILLE
WASHER
PAN
GLASS
SHADE
ROD
WASHER
FINIAL
NUT
Page 3
BLACK
RECEPTACLE
(FAN)
GRILLE
SCREW
WASHER
60 WATT
MAX.
B10 BASE
BULBS