DECORATIVE
CEILING VENTILATOR
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
S H O C K , O R I N J U RY TO P E R S O N S ,
OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer at the address or telephone number
listed in the warranty.
2. Before servicing or cleaning unit, switch power off
at service panel and lock the service disconnecting
means to prevent power from being switched on
accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be
done by qualified personnel in accordance with
all applicable codes and standards, including
fi re-rated construction codes and standards.
4. Suffi cient air is needed for proper combustion and
exhausting of gases through the fl ue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National
Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. NEVER place a switch where it can be reached from
a tub or shower.
8. This unit must be grounded.
9. This unit is cULus listed. Type I.C. inherently protected.
10. When applicable local regulations comprise more
restrictive installation and/or certifi cation requirements,
the aforementioned requirements prevail on those of
this document and the installer agrees to conform to
these at his own expenses.
11. When performing installation, servicing or cleaning
this unit, it is recommended to wear safety glasses
and gloves.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. This product is designed for installation in FLAT
CEILINGS ONLY. Do not mount this product in a wall.
3. The light fi xture assembly must be mounted to the
fan housing assembly included with this product. Do
not mount the light fi xture assembly to a
wiring outlet box.
4. To avoid motor bearing damage and noisy and/or
unbalanced impellers, keep drywall spray, construction
dust, etc. off power unit.
5. Please read specifi cation label on product for further
information and requirements.
All manuals and user guides at all-guides.com
Register your product
online at www.broan.ca
TYPICAL INSTALLATIONS
BH0012A
HOUSING MOUNTED
DIRECTLY TO JOIST
2 x 6 (or larger)
Discharge parallel to joists.
BH0014A
HOUSING MOUNTED
TO 2 x 4 TRUSS
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
BH0016A
HOUSING MOUNTED TO "I" JOIST
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
*Additional framing must be a 2 x 6 (minimum height), at least 9-inch long.
Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 4.
BB0008
BH0013A
HOUSING MOUNTED
TO ADDITIONAL FRAMING
Discharge 90° to joists.
*
BH0015A
HOUSING MOUNTED
TO 2 x 4 TRUSS
Requires additional framing
for mounting tabs.
Discharge 90° to joists.
*
BH0017A
HOUSING MOUNTED TO "I" JOIST
Requires additional framing
for mounting tabs.
Discharge 90° to joists.
MODEL 757SNC