Terminal
Tip.
Description
1 - 2com
NO
START CONTACT (Each impulse OPEN/STOP/CLOSE/STOP)
3 - 2com
NO
PEDESTRIAN CONTACT
4 - 6com
NC
SAFETY BAND OR OPENING PHOTOCELLS (If no use make bridge)
5 - 6com
NC
CLOSING PHOTOCELLS (If no use make bridge)
7 - 6com
NC
STOP contact(If no use make bridge)
9 - 8com
NC
LIMIT SWITCH OPENING
10 - 8com
NC
LIMIT SWITCH CLOSING
11 - 12
24V ~
Power service or accessories (output 24Vac 250mA)
13-14-15
Input ENGINE (13-14 input phases with capacitor in parallel) (15 common)
230V ~
16 - 18
230V ~
FLASH
17 - 18
230V ~
COURTESY LIGHT
19 - 20
230V ~
Input POWER 110Vac
21 - 22
Input ANTENNA ( 22 signal)
Example wiring selector
2
1
7
6
CONTACT
CONTACT
NO
NC
Start
Stop
Example wiring photocells
11 12
5
6
+ -
+ -
NC COM
RX
TX
TECHNICAL SPECIFICATIONS
Power
Power engine
Output accesories
Time for automatic close
Time for maneuver
Time for slow down
Time for courtesy light
Nr codes storable
Transmitters type
Frequency
Temperature to work
Sensibility
Homologation
FLASHING OPERATION WITH DIP6 ON
IN OPENING:
Flash slow
IN CLOSING:
Flash fast
IN PAUSE:
Steady light
PHOTOCELL ENGAGED: Turn off
TRIMMER T1
The trimmer POWER regulates the torque and sensitivity during the maneuver
TRIMMER T2
The trimmer POWER SLOW regulates the torque and sensitivity during SLOW DOWN phase
-
+
The TORQUE increases turning the trimmer in clockwise sense.
BUTTON
P1
o r R A D I O P R O G f o r s t o r a g e t h e t r a n s m i t t e r
BUTTON
P2
o r P R O G T I M E f o r s t o r a g e t h e s t r o k e
TABLED LEDS
L1
Led STATUS
Lit when the unit is powered
L2
Led RADIO
Lit when accessing in radio storage
L3
Led PROG. TIME
It is blinking when in programming
L4
Led START
Lit when taking a pulse
L5
Led PEDESTRIAN
Lit when taking a pedestrian pulse
L6
Led FOTOCELLS
Lit when the fotocells are aligned
L7
Led L.S. OPENING
Lit when limitswitch opening is on NC
L8
Led L.S. CLOSING
Lit when limitswitch closing is on NC
L7+L8
Led STOP
Both on when the stop is on NC
230V AC +/- 10%
550 W
24V AC 250mA
5 a 120 sec
3 a 120 sec
2 a 120 sec
180 sec
254 code
Fix\Roll-code
433.92 / 868 Mhz
-20 a 70°C
Better of –100dBm
Conf ETS 300-220/ETS 300-683