4. The 230V-input is protected by the fuse, which is located at the back of the device. Replace a blown fuse
with an identical one.
5. This device is protected against brief short circuits and equipped with an automatic reset function.
5.
Cleaning and Maintenance
Disconnect the device from the mains prior to maintenance activities.
The power supply cables must not show any damage. Have a qualified technician maintain the device.
Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
There are no user-serviceable parts, apart from the fuse. Contact your dealer for spare parts if necessary.
Store the device in a dry, well-ventilated, dust-free room.
6.
Technical Specifications
input voltage
230 V
output voltage
13.8 V
output current
3 A
ripple voltage
=/< 100 mVp-p
dimensions
110 × 80 × 200 mm
weight
1 kg
fuse
T1
Use this device with original accessories only. Velleman nv cannot be held responsible in the event
of damage or injury resulting from (incorrect) use of this device.
For more info concerning this product and the latest version of this manual, please visit our website
www.velleman.eu.
The information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part of this
manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise without the
prior written consent of the copyright holder.
V. 01 – 01/09/2014
FPS1303SM
50 Hz
3
©Velleman nv